參數(shù)資料
型號(hào): HS1-1840ARH
廠商: Intersil Corporation
英文描述: Radiation Hardened 16 Channel CMOS Analog Multiplexer with High-Z Analog Input Protection
中文描述: 輻射硬化的高16通道CMOS模擬多路復(fù)用器,模擬輸入保護(hù)尬
文件頁數(shù): 3/13頁
文件大?。?/td> 193K
代理商: HS1-1840ARH
3
Specifications HS-1840RH
Absolute Maximum Ratings
Reliability Information
Supply Voltage Between Pins 1 and 27 . . . . . . . . . . . . . . . . . . +40V
+VSUPPLY to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20V
-VSUPPLY to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20V
VREF to Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20V
Analog Input Overvoltage
+VS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+25V (Power On/Off)
-VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -25V (Power On/Off)
Digital Input Overvoltage
+VEN, +VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VREF +4V
-VEN, -VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND -4V
Continuous Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10mA
Storage Temperature Range . . . . . . . . . . . . . . . . . -65
o
C to +150
o
C
Junction Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +175
o
C
Lead Temperature (Soldering 10s). . . . . . . . . . . . . . . . . . . . +275
o
C
Thermal Resistance . . . . . . . . . . . . . . . . . .
Sidebraze Package . . . . . . . . . . . . . . . . .
Flatpack Package . . . . . . . . . . . . . . . . . .
Total Power Dissipation (Note)
Sidebraze CerDIP Package. . . . . . . . . . . . . . . . . . . . . . . 1600mW
Ceramic Flatpack Package . . . . . . . . . . . . . . . . . . . . . . . 1400mW
ESD Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
θ
JA
θ
JC
83.1
o
C/W
49.1
o
C/W
19.1
C/W
16.5
o
C/W
NOTE: For DIP Derate 20.4mW/
o
C above T
A
= +95
o
C
For Flatpack Derate 18.5mW/
o
C above T
A
= +95
o
C
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Operating Conditions
Operating Supply Voltage (
±
VSUPPLY)
. . . . . . . . . . . . . . . . . . . . ±
15V
Operating Temperature Range. . . . . . . . . . . . . . . . -55
o
C to +125
o
C
VREF (Pin 13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5V
Logic Low Level (VAL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.8V
Logic High Level (VAH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +4.0V
TABLE 1. DC ELECTRICAL PERFORMANCE CHARACTERISTICS
Device Guaranteed and 100% Tested. Unless Otherwise Specified: V- = -15V, V+ = +15V, VREF = +5V, VAH = +4.0V, VAL = 0.8V
PARAMETER
SYMBOL
CONDITIONS
GROUP A
SUBGROUPS
TEMPERATURE
LIMITS
UNITS
MIN
MAX
Analog Signal Range
VS
7, 8A, 8B
-55
o
C, +25
o
C,
+125
o
C
-5
+15
V
Input Leakage
Current, Address, or
Enable Pins
IAH
IAL
Measure Inputs Sequentially
Ground All Unused Pins
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
Leakage Current Into
the Source Terminal of
an “Off” Switch
+IS(OFF)
VS = +10V, All Unused Inputs
and Output = -10V, VEN = 4V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C,-55
o
C
-100
100
nA
-IS(OFF)
VS = -10V, All Unused Inputs,
Output = +10V, VEN = 4V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
Leakage Current into
the Source Terminal of
an “Off” Switch With
Power “Off”
+IS(OFF)
Power Off
V+, V-, VREF, A0, A1, A2, A3,A4,
EN = GND, Unused Inputs Tied to
GND, VS = +25V
1
+25
o
C
-50
50
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
Leakage Current Into
the Source Terminal of
an “Off” Switch With
Overvoltage Applied
+IS(OFF)
Overvoltage
VS = +25V, VD = 0V, VEN = 4V
All Unused Inputs Tied to GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
-IS(OFF)
Overvoltage
VS = -25V, VD = 0V, VEN = 4V All
Unused Inputs Tied to GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
Leakage Current Into
the Drain Terminal of
an “Off” Switch
+ID(OFF)
VD = +10V, VEN = 4V All Unused
Inputs = -10V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
-ID(OFF)
VD = -10V, VEN = 4V All Unused
Inputs = +10V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
Leakage Current Into
the Drain Terminal of
an “Off” Switch With
Overvoltage Applied
+ID(OFF)
Overvoltage
VS = +25V, Measure VD,
VEN = 4V, All Unused Inputs to
GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
-ID(OFF)
Overvoltage
VS = -25V, Measure VD,
All Unused Inputs to GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
Spec Number
518022
相關(guān)PDF資料
PDF描述
HS-2603 Cyrix Geode GX1 Embedded Engine Board
HS-2800 Header; No. of Contacts:50; Pitch Spacing:0.079"; No. of Rows:2; Gender:Male; Series:1552; Body Material:Glass Filled Polyester; Connector Retention Style:Latch/Ejector; Contact Termination:Through Hole; Housing Style:Right-Angle RoHS Compliant: Yes
HS-2810 MINIBOB, EXL, 6AFN, 25X25X5; RoHS Compliant: NA
HS-2840 CRYSTAL CLOCK OSCILLATORS
HS-2841 CRYSTAL CLOCK OSCILLATORS
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
HS1-1840ARH/PROTO 制造商:Intersil Corporation 功能描述:ANLG MUX SGL 16:1 28PIN SBDIP - Rail/Tube
HS1-1840ARH-8 制造商:Intersil Corporation 功能描述:ANLG MUX SGL 16:1 28CDIP - Rail/Tube
HS1-1840ARH-Q 制造商:INTERSIL 制造商全稱:Intersil Corporation 功能描述:Rad-Hard 16 Channel CMOS Analog Multiplexer with High-Z Analog Input Protection
HS1-1840ARH-T 制造商:Intersil Corporation 功能描述:ANLG MUX SGL 16:1 28PIN SBDIP - Rail/Tube
HS1-1840BRH 制造商:INTERSIL 制造商全稱:Intersil Corporation 功能描述:Rad-Hard 16 Channel CMOS Analog Multiplexer with High-Z Analog Input Protection