HM5264165F/HM5264805F/HM5264405F-75/A60/B60
34
Write with auto precharge to Read command interval
1. Different bank:
When some banks are in the active state, the second read command (another bank) is
executed. However, in case of a burst write, data will continue to be written until one clock before the read
command is executed. The internal auto-precharge of one bank starts at the next clock of the second
command.
Write with Auto Precharge to Read Command Interval
(Different bank)
CLK
Command
BS
Dout
Din
WRIT A
READ
out B0
out B1
out B2
out B3
CAS
Latency = 3
Burst Length = 4
bank0
Write A
bank3
Read
Note: Internal auto-precharge starts at the timing indicated by " ".
DQM,
DQMU/DQML
in A0
Same bank:
The consecutive read command from write with auto precharge (the same bank) is illegal. . It is
necessary to separate the two commands with a bank active command.