1
High
Density
-
Board
Mounted
Power
Division
Powering Communications and Technology
50
55
60
65
70
75
80
85
90
95
12345
6789
10
X10 = LOAD %
EFFICIENCY
%
HES033ZE
HES075ZG
HES100ZE
TECHNICAL SPECIFICATIONS
HES single output DC/DC converters provide up to
150 Watts of output power in an industry standard,
half-brick package and footprint. These units feature
ultra-high efficiency, Class A conducted noise specs,
and fixed switching frequency. The HES is designed
with open-frame packaging, along with planar
magnetics to provide maximum useable power with
minimal thermal constraints. The HES is especially
suited to harsh telecom, networking, and industrial
applications, and is fully compatible with production
board washing processes.
High Efficiency
Industry Standard Half-
Brick
Open-Frame Packaging
100°C Baseplate
Operation
Water Washable
“True-Trim” Option
1500V Isolation
Positive or Negative
Logic
DESCRIPTION
FEATURES
HES SERIES
150 WATT
Turn-On Time
10 ms
Remote Shutdown
Positive Or Negative Logic
Remote Shutdown Reference
Vin Negative
Switching Frequency 2.5 & 3.3, 5V Model
200 kHz, 300 kHz (Respectively)
Isolation
Input - Output
1500 VDC
Input - Case
1050 VDC
Output - Case
500 VDC
Temperature Coefficient
0.02%/°C
Case Temperature
Operating Range
-40 To +100°C
Storage Range
-40 To +125°C
Thermal Shutdown Range
105 To 115°C
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
MTBF (Bellcore Tr-nwt-000332)
1.8 X 106 hrs
Safety
UL 1950, Csa 22.2-950, En60950
Weight (Approx.)
1.4 oz
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
Setpoint Accuracy
±1%
Line Regulation Vin Min. - Vin Max., Iout Rated
0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom.
0.2% Vout
Remote Sense Headroom
0.5 VDC
Minimum Output Current
10 %
Dynamic Regulation, Loadstep
25% Iout
Pk Deviation
4% Vout
Settling Time
500 ms
Voltage Trim Range
±10%
Short Circuit / Overcurrent Protection
Shutdown / Hiccup
Current Limit Threshold Range, % of Iout Rated
110 - 130%
OVP Trip Range
120 - 140% Vout Nom.
OVP Type
Self Recovering
Voltage Range
24 VDC Nominal
18 - 36 VDC
48 VDC Nominal
36 - 72 VDC
Reflected Ripple
50 mA
Input Reverse Voltage Protection
Shunt Diode
Input Undervoltage Lockout / Hysteresis
<34V/1V Nom.
Output
Input
Efficiency vs. Load (48V Input)
Notes
General