353
ST:
Step Time. This is the time the FLEX decoder is to wait before applying the next state’s
receiver control value to the receiver control lines. The setting is in steps of 625μs. Valid values
are 625μs (ST=01) to 79.375ms (ST=7F in hexadecimal). (value after reset=625μs)
3. 3200sps Sync Setting Packets
Table 12-13 3200sps Sync Setting Packet Bit Assignments
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 3
0
0
0
1
0
1
1
0
Byte 2
0
0
0
0
LBC
0
0
0
Byte 1
CLS
7
0
CLS
6
ST
6
CLS
5
ST
5
CLS
4
ST
4
CLS
3
ST
3
CLS
2
ST
2
CLS
1
ST
1
CLS
0
ST
0
Byte 0
LBC:
Low Battery Check. If this bit is set, the FLEX decoder will check the status of the LOBAT
port just before leaving this receiver state. (value after reset=0)
CLS:
Control Line Setting. This is the value to be output on the receiver control lines (S0-S7) for
this receiver state. (value after reset=0)
ST:
Step Time. This is the time the FLEX decoder is to wait before expecting good signals on the
EXTS1 and EXTS0 signals after warming up. The setting is in steps of 625μs. Valid values are
625μs (ST=01) to 79.375ms (ST=7F in hexadecimal). (value after reset=625μs)
4. Receiver On Setting Packets
Table 12-14 Receiver On Setting Packet Bit Assignments
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 3
0
0
0
1
s
3
LBC
s
2
0
s
1
0
s
0
0
Byte 2
0
0
0
0
Byte 1
CLS
7
0
CLS
6
0
CLS
5
0
CLS
4
0
CLS
3
0
CLS
2
0
CLS
1
0
CLS
0
0
Byte 0