21
H7CR
H7CR
Item
Input mode
(default)
Applicable Counters
H7CR-A, H7CR-SA
H7CR-B, H7CR-SB
H7CR-C, H7CR-SC
H7CR-8, H7CR-11
Description
Determines the input mode:
Up, Down, Reversible A, Reversible B,
Reversible C
Press the Up key until the desired
mode is displayed.
Setting values
Increment keys 1 to 6 change the display.
*There is no Up or Down mode for H7CR-C
and H7CR-SC (+/– range) counters.
Output mode
and OUT 2
output time
H7CR-A, H7CR-SA
H7CR-B, H7CR-SB
H7CR-C, H7CR-SC
H7CR-8, H7CR-11
Determines the operation of the
control outputs. Refer to "Output
Operations" tables for details. Also
determines the output time for control
output (OUT2) in single preset
counters.
Increment keys 1 to 6 change output mode.
OUT 1
output time
H7CR-B, H7CR-SB
H7CR-C, H7CR-SC
(double preset models only)
Designates the output time for
output 1 (double preset models only).
Press the increment keys to set the
desired time for output 1.
Increment keys 1 to 6 change output time.
*Hold mode is available only on H7CR-BW
and H7CR-SBW counters.
(Applicable to output modes C, R, K, P, Q,
and A only.)
Counting speed
H7CR-A, H7CR-SA
H7CR-B, H7CR-SB
H7CR-C, H7CR-SC
H7CR-8, H7CR-11
Changes the input filter for counting
inputs. Used to prevent counting
errors caused by input interference.
Press the increment keys to set the
desired speed. A "k" on the display
indicates kilocycles (1000 cycles).
Increment keys 1 to 6 change count speed.
Minimum reset
times
H7CR-B, H7CR-SB
H7CR-C, H7CR-SC
H7CR-8, H7CR-11
Determines the minimum time
required for the reset input.
Press any increment key to switch
between 1 and 20 ms.
Increment keys 1 to 6 change reset time.
Item
Preset 1, H7CR-B, H7CR-SB
Preset 2 H7CR-C, H7CR-SC
set value
Applicable Counters
Description
Determine the timing of the outputs in comparison to
the present count value according to the output mode.
The DISPLAY key switches between set value 1 and 2 in
double preset models. Use the increment keys (1 to 6)
to change a digit.
Setting values
Sequence when changing a digit
using the increment keys (1 to 6).
Minus sign displayed for leftmost
digit of H7CR-C and H7CR-SC
(+/– range counters) by using
increment key 6.
I
SUMMARY OF SETTING PROCEDURES
Run Mode
the counter is ready to accept setting changes to default items.
Setting Mode
Up Down Reversible A Reversible B Reversible C
Note
: Settings changed in the Setting mode are effective only after returning to the Run mode.
1 ms
20 ms