GB202A VER: 3.0
-
16 -
Issue date: 2006/07/31
JEWEL HILL ELECTRONIC CO.,LTD
.
9. RELIABILITY
9.1. MTBF
The LCD module shall be designed to meet a minimum MTBF value of 50000 hours with normal.
(25°C in the room without sunlight)
9.2. TESTS
NO.
ITEM
CONDITION
CRITERION
No Defect Of
Operational Function In
Room Temperature Are
Allowable.
IDD of LCM in
Pre-and post-test should
follow specification
1
High Temperature Operating
60
120Hrs
2
Low Temperature Operating
-10
120Hrs
3
High Temperature/
Humidity Non-Operating
60
,90%RH ,120 Hrs
4
High Temperature
Non-Operating
70
120Hrs
5
Low Temperature
Non-Operating
-20
120Hrs
6
Temperature Cycling
Non-Operating
-10
(30Min )
60
10 CYCLES
(30Min)
Notes: Judgments should be mode after exposure in room temperature for two hours.