參數(shù)資料
型號: G6L-1F-TR12VDC
元件分類: 功率/信號繼電器
英文描述: POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.015A (COIL), 12VDC (COIL), 180mW (COIL), 1A (CONTACT), 24VDC (CONTACT), SURFACE MOUNT-STRAIGHT
文件頁數(shù): 8/8頁
文件大?。?/td> 180K
代理商: G6L-1F-TR12VDC
56
G6L
G6L
Precautions
Refer to page 25 for information on general precautions. Be sure
to read these precautions before using the Relay.
Correct Use
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the contact
surfaces. Be sure to use a fail-safe circuit design that provides
protection against contact failure or coil burnout.
Relay Handling
Use the Relay as soon as possible after opening the moisture-
proof package. If the Relay is left for a long time after opening the
moisture-proof package, the appearance may suffer and seal
failure may occur after the solder mounting process. To store the
Relay after opening the moisture-proof package, place it into the
original package and sealed the package with adhesive tape.
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep the
solvent temperature to less than 40oC. Do not put the Relay in a
cold cleaning bath immediately after soldering.
Soldering
Soldering temperature: Approx. 250oC (At 260oC if the DWS
method is used.)
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used.)
Be sure to adjust the level of the molten solder so that the solder
will not overflow onto the PCB.
Claw Securing Force During Automatic Insertion
During automatic insertion of Relays, make sure to set the
securing force of the claws to the following values so that the
Relay characteristics will be maintained.
Environmental Conditions During Operation, Storage, and
Transportation
Protect the Relays from direct sunlight and keep the Relays under
normal temperature, humidity, and pressure.
Maximum Voltage
The maximum voltage of the coil can be obtained from the coil
temperature increase and the heat-resisting temperature of coil
insulating sheath material. (Exceeding the heat-resisting
temperature may result in burning or short-circuiting.) The
maximum voltage also involves important restrictions which
include the following:
Must not cause thermal changes in or deterioration of the
insulating material.
Must not cause damage to other control devices.
Must not cause any harmful effect on people.
Must not cause fire.
Therefore, be sure not to exceed the maximum voltage specified
in the catalog.
As a rule, the rated voltage must be applied to the coil. A voltage
exceeding the rated value, however, can be applied to the coil
provided that the voltage is less than the maximum voltage. It
must be noted that continuous voltage application to the coil will
cause a coil temperature increase thus affecting characteristics
such as electrical life and resulting in the deterioration of coil
insulation.
Coating
Relays mounted on PCBs may be coated or washed. Do not
apply silicone coating or detergent containing silicone, otherwise
the silicone coating or detergent may remain on the surface of the
Relays.
Coil Power Supply Waveform
If the voltage applied to the coil is increased or decreased
gradually, operating characteristics may be unstable, contact
endurance may decline, or the Relay may not function at its full
performance level. Therefore, always use an instantaneous ON
and instantaneous OFF when applying the voltage. Be sure that
the rated voltage or zero voltage is reached within 1 ms.
A
C
B
Direction A: 5.0 N max.
Direction B: 5.0 N max.
Direction C: 5.0 N max.
Secure the claws to the area indicated by shading.
Do not attach them to the center area or to only part of the
Relay.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K119-E1-02
相關(guān)PDF資料
PDF描述
G6L-1F-TR24VDC POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.01A (COIL), 24VDC (COIL), 180mW (COIL), 1A (CONTACT), 24VDC (CONTACT), SURFACE MOUNT-STRAIGHT
G6L-1F-TR3VDC POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.06A (COIL), 3VDC (COIL), 180mW (COIL), 1A (CONTACT), 24VDC (CONTACT), SURFACE MOUNT-STRAIGHT
G6L-1F-TR4.5VDC POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.04A (COIL), 4.5VDC (COIL), 180mW (COIL), 1A (CONTACT), 24VDC (CONTACT), SURFACE MOUNT-STRAIGHT
G6L-1F-TR5VDC POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.036A (COIL), 5VDC (COIL), 180mW (COIL), 1A (CONTACT), 24VDC (CONTACT), SURFACE MOUNT-STRAIGHT
G6SU-2F-DC5
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
G6L1FTRDC12 制造商:Omron Electronic Components LLC 功能描述:EM RLY SPST-NO 1A 12VDC 800OHM SMD - Tape and Reel 制造商:Omron Electronic Components LLC 功能描述:RELAY TELECOM SPST 1A 12V
G6L-1F-TRDC12 功能描述:RELAY TELECOM SPST 1A 12V RoHS:是 類別:繼電器 >> 信號,高達(dá) 2 A 系列:G6L 其它有關(guān)文件:Relay Technical Info Standards Chart 產(chǎn)品變化通告:AGQ Series Nominal Capacity Change 18/Jul/2011 標(biāo)準(zhǔn)包裝:50 系列:AGQ 繼電器類型:電信 線圈類型:鎖存,單線圈 線圈電流:8.3mA 線圈電壓:12VDC 觸點形式:DPDT(2 C 型) 觸點額定值(電流):2A 切換電壓:125VAC,110VDC - 最小值 關(guān)閉電壓(最大):9 VDC 關(guān)閉電壓(最?。?- 特點:- 安裝類型:表面貼裝 端接類型:鷗翼型 包裝:管件 觸點材料:銀鈀(AgPd),金(Au) 操作時間:4ms 釋放時間:4ms 線圈功率:100 mW 線圈電阻:1.44 千歐 工作溫度:-40°C ~ 85°C
G6L-1F-TR-DC12 功能描述:低信號繼電器 - PCB 12VDC SPST-NO Low profile T and R RoHS:否 制造商:NEC 觸點形式:2 Form C (DPDT-BM) 觸點電流額定值: 線圈電壓:5 V 最大開關(guān)電流:1 A 線圈電流:1 A 線圈類型:Non-Latching 功耗:140 mW 端接類型:SMT 絕緣: 介入損耗:
G6L1FTRDC12TR 制造商:Omron Electronic Components LLC 功能描述:- Tape and Reel
G6L1FTRDC24 制造商:Omron Electronic Components LLC 功能描述:EM RLY SPST-NO 1A 24VDC 2.504KOHM SMD - Rail/Tube 制造商:Omron Electronic Components LLC 功能描述:RELAY TELECOM SPST 1A 24V 制造商:Omron Electronic Components LLC 功能描述:Electromechanical Relay SPST-NO 1A 24VDC 2.504KOhm Surface Mount