65
G6H
G6H
■
Characteristics
Note:
Note:
The above values are initial values.
1.
The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2.
Values in parentheses are actual values.
3.
The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength. (The insulation resistance between the set and reset coil (G6HK-2 only), however, is 100 M
min. when
measured with a 125-VDC megohmmeter.)
■
Approved Standards
UL114, UL478 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928)
Contact resistance (See note 1.)
Operate (set) time (See note 2.)
50 m
max. (G6H-2-U: 100 m
max.; G6H-2F: 60 m
max.)
Single-side stable types: 3 ms max. (approx. 2 ms)
Latching types: 3 ms max. (approx. 1.5 ms)
Single-side stable types: 2 ms max. (approx. 1 ms)
Latching types: 3 ms max. (approx. 1.5 ms)
Latching type: 5 ms min. (at 23
°
C)
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 M
min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
125 VAC, 50/60 Hz for 1 min between set and reset coil (only G6HK-2)
1,500 V (10 x 160
μ
s) between contacts of same polarity (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3-mm double amplitude)
Destruction: 1,000 m/s
2
Malfunction: 500 m/s
2
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 200,000 operations min. (at 1,800 operations/hr)
Operating:
40
°
C to 70
°
C (with no icing)
Operating: 5% to 85%
Approx. 1.5 g
Release (reset) time (See note 2.)
Min. set/reset signal width
Max. operating frequency
Insulation resistance (See note 3.)
Dielectric withstand voltage
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Model
Contact form
DPDT
Coil ratings
1.5 to 48 VDC
Contact ratings
G6H-2
G6HU-2
G6HK-2
G6H(U/K)-2-U
G6H(U/K)-2-100
2 A, 30 VDC
0.3 A, 110 VDC
0.5 A, 125 VAC