2
G6E
G6E
Specifications
I
CONTACT DATA
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
Resistive load (p.f. = 1)
0.40 A at 125 VAC, 2 A at 30 VDC
Ag (Au clad)
3 A
250 VAC, 220 VDC
3 A (AC), 3 A (DC)
50 VA, 60 W
10
μ
A, 10 mVDC
Inductive load (p.f. = 0.4) (L/R = 7 ms)
0.20 A at 125 VAC, 1 A at 30 VDC
1.50 A (AC), 1.50 A (DC)
25 VA, 30 W
I
COIL DATA
Standard non-latching (G6E-134P-ST-US)
Coil inductance
(ref. value) (H)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature
OFF
Armature
ON
% of rated voltage
70% max.
3
5
6
9
12
24
48
66.70
40
33.30
22.20
16.70
8.30
8.30
45
125
180
405
720
2,880
5,760
0.08
0.18
0.31
0.62
1.20
4.70
5.35
0.06
0.17
0.24
0.50
0.99
3.90
5.12
10% min.
190% max.
at 23
°
C
(73
°
F)
Approx. 200
115% max.
at 70
°
C
(158
°
F)
Approx. 400
Low-sensitivity non-latching type (G6E-134PL-ST-US)
Coil inductance
(ref. value) (H)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature
OFF
Armature
ON
% of rated voltage
70% max.
3
5
6
9
12
24
133
79.40
66.60
44.30
33.30
16.70
22.50
63
90
203
260
1,440
0.03
0.08
0.12
0.21
0.45
1.77
0.03
0.07
0.10
0.19
0.42
1.65
10% min.
190% max.
at 23
°
C
(73
°
F)
Approx. 400
115% max.
at 70
°
C
(158
°
F)
Standard single coil latching type (G6EU-134P-ST-US)
Coil inductance
(ref. value) (H)
Set
pick-up
voltage
Reset
pick-up
voltage
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
)
Maximum
voltage
Power
consumption
(mW)
Armature
OFF
Armature
ON
% of rated voltage
70% max.
3
5
6
9
12
24
66.70
40
33.30
22.20
16.70
8.30
4.50
125
180
405
720
2,880
0.05
0.13
0.19
0.45
0.84
3.56
0.04
0.12
0.17
0.40
0.79
3.10
70% min.
190% max.
at 23
°
C
(73
°
F)
Approx. 200
130% max.
at 70
°
C
(158
°
F)
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C (73
°
F) with a tolerance of
±
10%.
2. The operating characteristics are measured at a coil temperature of 23
°
C (73
°
F).