2
G4W
G4W
Contact resistance
Operate time
Release time
Bounce time
Operating frequency
30 m
20 ms max. (mean value: approx. 13 ms)
5 ms max. (mean value: approx. 2.50 ms)
Operate: approx. 0.40 ms
18,000 operations/hour
1,800 operations/hour (under rated load)
100 M
min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 minute between coil and contacts
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,500 VAC, 50/60 Hz for 1 minute between contacts of same pole
10,000 VAC, 1.20 x 50
μ
s (between coil and contacts)
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range
1,000 m/s
2
(approx. 100 G)
150 m/s
2
(approx. 15 G)
-25
°
to 55
°
C (-13
°
to 131
°
F)
-25
°
to 55
°
C (-13
°
to 131
°
F)
35% to 85% RH
5,000,000 operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
29 g (1.02 oz)
Mechanical
Electrical
Insulation resistance
Dielectric strength
Impulse dielectric strength
Vibration
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Storage
Shock
Ambient temperature
Humidity
Service life
Mechanical
Electrical
Weight
I
CHARACTERISTIC DATA
Maximum switching capacity
SPST-NO, DPST-NO
Electrical service life
SPST-NO, DPST-NO
Rated operating voltage (V)
R
Note: Data shown are of initial value.
I
CHARACTERISTICS
Rated operating current (A)
S
3
I
COIL DATA
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
)
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF
0.93
1.90
3.70
61.80
Armature ON
1.65
3.30
6.40
106
% of rated voltage
80% max.
12
18
24
100
66.70
44.40
33.30
8
180
405
720
12,500
10% min.
110% max.
Approx. 800
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C (73
°
F) with a tolerance of
±
10%.
2. The operating characteristics are measured at a coil temperature of 23
°
C (73
°
F).