Precautions
WARNING
Always turn the power off before wiring, otherwise an electric
shock may occur.
Do not touch the SSR terminal section (the recharge section)
while the power supply is connected. Contact with the re-
charge section will result in an electric shock.
Caution
Do not use excess voltage or current in the SSR input or output cir-
cuits. Otherwise, damage to the SSR or a fire will result.
Conduct wiring and soldering correctly according to soldering con-
ditions. If the product is used with incomplete wiring, overheating
will occur and may result in a fire.
3
OPTIMUM OPERATING CONDITIONS
Part number
G3VM-2/2F, G3VM--3/3F, G3VM--3L/3FL,
G3VM--S2, G3VM--S3, G3VM--SW,
G3VM--W/WF
G3VM-6/6F
Min.
---
5.0mA
---
--20
°
C
Typ.
---
7.5mA
---
---
Max.
280V
25mA
100mA
65
°
C
Min.
---
10mA
---
--20
°
C
Typ.
---
15mA
---
---
Max.
280V
25mA
120mA
80
°
C
Supply voltage
LED Forward current
Output current
Operating temperature
Part number
G3VM-V/VF, G3VM--SY
Min.
---
7.5mA
---
--20
°
C
G3VM-S5
Min.
---
5.0mA
---
--20
°
C
Typ.
---
15mA
---
---
Max.
48V
25mA
300mA
80
°
C
Typ.
150V
7.5mA
---
---
Max.
200V
25mA
120mA
65
°
C
Supply voltage
LED Forward current
Output current
Operating temperature
3
TEMPERATURE DERATINGS
Part number
LED forward current derating
Continuous load current derating
G3VM 2/2F G3VM S2
G3VM-2/2F, G3VM--S2
--0.5mA/
°
C
--1.2mA/
°
C
G3VM S5
G3VM-S5
--0.5mA/
°
C
--1.5mA/
°
C
G3VM SY
G3VM-SY
--0.5mA/
°
C
--3.0mA/
°
C
Part number
G3VM-3/3F, G3VM--3L/3FL,
G3VM--S3
--0.5mA/
°
C
--1.2mA/
°
C
--1.2mA/
°
C
--1.6mA/
°
C
G3VM-6/6F
G3VM-V/VF
LED forward current derating
Continuous load
current derating
--0.3mA/
°
C
--1.5mA/
°
C
--2.0mA/
°
C
--3.0mA/
°
C
--0.5mA/
°
C
--3.0mA/
°
C
--4.5mA/
°
C
--6.0mA/
°
C
Connection A
Connection B
Connection C
Part number
LED forward current derating
Continuous load
current derating
G3VM SW G3VM W/WF
G3VM-SW, G3VM--W/WF
--0.5mA/
°
C
--1.2mA/
°
C
--1.0mA/
°
C
One channel
Both channels
!