Replacement Relays
Replacement Relays
2
3
OUTPUT RELAYS G2R-1-S AND G2R-1-SN
Coil Ratings
Rated voltage
Rated current (50/60 Hz)
Coil resistance
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
24 VDC
21.8 mA
1,100
4.27
8.55
70% min. of rated voltage
15% min. of rated voltage
110% of rated voltage
Approx. 0.53 W
Armature OFF
Armature ON
Contact Ratings
Also refer to Ratings/Characteristics of G70A-ZIM16-5.
Number of poles
Load
Rated load
Rated carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
1 pole
Resistive load (p.f. = 1)
10 A at 250 VAC; 10 A at 30 VDC
10 A
380 VAC, 125 VDC
10 A
2,500 VA, 300 W
100 mA at 5 VDC
Inductive load (p.f. = 0.4; L/R = 7 ms)
7.5 A at 250 VAC; 5 A at 30 VDC
1,875 VA, 150 W
G3R Solid State Relay
3
ORDERING INFORMATION
Input Relays
App
base
Isolation
Indicator
Response
speed
Logic level
Supply
voltage
4 to
32 VDC
Rated inp
voltage
Part number
Supply
current
0.1 to
100 mA
G70A relay
G730 RIA I/O
base, G730-RIA I/O
modules (Refer to
G70A and G730-R
G70A and G730 R
data sheets for
specific models)
Photo-
coupler
Yes
------
High-speed
100 to 240 VAC
5 VDC
12 to 24 VDC
5 VDC
12 to 24 VDC
G3R-IAZR1SN AC100-240
G3R-IDZR1SN DC5
G3R-IDZR1SN DC12-24
G3R-IDZR1SN-1 DC5
G3R-IDZR1SN-1 DC12-24
Low-speed
Output Relays
Applicable block base
Isolation
Indicator
Zero cross
function
Yes
No
------
Applicable
output load
2 A at 75 to 264 VAC
Rated
input
5 to
24 VDC
Part number
G70A relay output base,
G730 RIA I/O
G730-RIA I/O mod l
(Refer to G70A and
G730-R data sheets for
G730 R data sheets for
specific models)
Phototriac
Yes
G3R-OA202SZN DC5-24
G3R-OA202SLN DC5-24
G3R-ODX02SN DC5-24
G3R-OD201SN DC5-24
Photocoupler
2 A at 4 to 60 VDC
1 A at 40 to 200 VDC