Replacement Relays
Replacement Relays
11
G6D Power Relay
3
ORDERING INFORMATION
Applicable block base
Classification
Applicable
load
5 A
Rated coil
voltage
5 VDC
12 VDC
24 VDC
Part number
G70D and G70D-R6-B7A output bases, SRT2-ROC08/-ROC16
d l
d l
output modules and G730 modules.
(Refer to G70D, G70D-R6-B7A, SRT
-R and G730-R data
sheets for specific models)
Output relay
G6D-1A DC5
G6D-1A DC12
G6D-1A DC24
3
RATINGS
Coil Ratings
Rated voltage
Rated current
Coil resistance
Must operate voltage
(See Note 1)
Must release voltage
Max. voltage
Power consumption
5 VDC
40 mA
125
70% max. of rated voltage
10% min. of rated voltage
130% of rated voltage
Approx. 200 mW
12 VDC
16.7 mA
720
24 VDC
8.3 mA
2,880
Note: 1.
The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
Rated current and coil resistance were measured at a coil temperature of 23
E
C with a tolerance of
á
10%.
Operating characteristics were measured at a coil temperature of 23
E
C.
The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply.
There is no continuous allowance.
2.
3.
4.
Contact Ratings
Load classification
Rated load
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
Life expectancy
Resistive load (p.f. = 1)
5 A at 250 VAC, 30 VDC
5 A
250 VAC, 30 VDC
5 A
1250 VA, 150 W
10 mA at 5 VDC
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (5 A at 250 VAC, resistive load)
100,000 operations min. (5 A at 30 VDC, resistive load)
300,000 operations min. (2 A at 250 VAC, resistive load)
300,000 operations min. (2 A at 30 VDC, resistive load)
(at 1,800 operations/hr)
Inductive load (p.f. = 0.40, L/R = 7 ms
2 A at 50 VAC, 30 vDC
500 VA, 60 W
3
CHARACTERISTICS
Contact resistance
(See Note 2)
Operate time
Release time
Insulation resistance
Dielectric strength
100 m
max.
10 ms max.
5 ms max.
1,000 M
min. at 500 VDC
3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
6,000 V, 1.2 x 50
μ
s between coil and contacts
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
Operating: --25
°
C to 70
°
C (--13
°
F to 158
°
F)
Operating: 45% to 85%
Approx. 3 g
Surge withstand voltage
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Note: 1.
The above values are initial values.
Measurement condition: 1 A at 5 VDC
2.