www.fairchildsemi.com
4
FXL4T245
DC Electrical Characteristics (Continued)
Note 4: VCCI = the VCC associated with the data input under test.
Note 5: VCCO = the VCC associated with the output under test.
Note 6: Don’t Care
= Any valid logic level.
Note 7: Reflects current per supply, VCCA or VCCB.
Symbol
Parameter
Conditions
VCCA
VCCB
Min
Max
Units
(V)
VOH
High Level Output Voltage
IOH = 100 A
1.1 - 3.6
VCC0 - 0.2
V
(Note 5)
IOH = 12 mA
2.7
2.2
IOH = 18 mA
3.0
2.4
IOH = 24 mA
3.0
2.2
IOH = 6 mA
2.3
2.0
IOH = 12 mA
2.3
1.8
IOH = 18 mA
2.3
1.7
IOH = 6 mA
1.65
1.25
IOH = 2 mA
1.4
1.05
IOH = 0.5 mA
1.1
0.75 x VCC0
VOL
Low Level Output Voltage
IOL = 100A
1.1 - 3.6
1.1- 3.6
0.2
V
(Note 5)
IOL = 12 mA
2.7
0.4
IOL = 18 mA
3.0
0.4
IOL = 24 mA
3.0
0.55
IOL =12 mA
2.3
0.4
IOL = 18 mA
2.3
0.6
IOL = 6 mA
1.65
0.3
IOL = 2 mA
1.4
0.35
IOL = 0.5 mA
1.1
0.3 x VCC0
II
Input Leakage Current. Control Pins VI = VCCA or GND
1.1 - 3.6
3.6
±1.0
A
IOFF
Power Off Leakage Current
An, VI or VO = 0V to 3.6V
0
3.6
±10.0
A
Bn, VI or VO = 0V to 3.6V
3.6
0
±10.0
IOZ
3-STATE Output Leakage
An, Bn
OE
= V
IH
3.6
±10.0
A
(Note 6)
0
≤ V
O ≤ 3.6V
Bn,
OE
= Don’t Care
0
3.6
+10.0
VI = VIH or VIL
An,
OE
= Don’t Care
3.6
0
+10.0
ICCA/B (Note 7) Quiescent Supply Current
VI = VCCI or GND; IO = 0
1.1 - 3.6
20.0
A
ICCZ (Note 7)
Quiescent Supply Current
VI = VCCI or GND; IO = 0
1.1 - 3.6
20.0
A
ICCA
Quiescent Supply Current
VI = VCCA or GND; IO = 0
0
1.1 - 3.6
10.0
A
VI = VCCA or GND; IO = 0
1.1 - 3.6
0
10.0
A
ICCB
Quiescent Supply Current
VI = VCCB or GND; IO = 0
1.1 - 3.6
0
10.0
A
VI = VCCB or GND; IO = 0
0
1.1 - 3.6
10.0
A
I
CCA/B
Increase in ICC per Input;
VIH = 3.0
3.6
500
A
Other Inputs at VCC or GND