      參數(shù)資料
      型號: FS2660-9EPD6TB2
      廠商: POWER-ONE INC
      元件分類: 電源模塊
      英文描述: 2-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
      封裝: METAL, CASE S02, MODULE
      文件頁數(shù): 2/33頁
      文件大?。?/td> 438K
      代理商: FS2660-9EPD6TB2
      S Series Data Sheet
      100 Watt AC-DC and DC-DC Converters
      APR 26, 2006 revised to SEP 25, 2006
      Page 10 of 33
      www.power-one.com
      Thermal Considerations
      If a converter is located in free, quasi-stationary air (convection
      cooling) at the indicated maximum ambient temperature TA max
      (see table: Temperature specifications) and is operated at its
      nominal input voltage and output power, the temperature
      measured at the Measuring point of case temperature TC (see:
      Mechanical Data) will approach the indicated value TC max after
      the warm-up phase. However, the relationship between TA and
      TC depends heavily on the conditions of operation and
      integration into a system. The thermal conditions are influenced
      by input voltage, output current, airflow and temperature of
      surrounding components and surfaces. TA max is therefore,
      contrary to TC max, an indicative value only.
      Caution: The installer must ensure that under all operating
      conditions TC remains within the limits stated in the table
      Temperature specifications.
      Notes: Sufficient forced cooling or an additional heat sink allows TA
      to be higher than 71
      °C (e.g., 85 °C) if TC max is not exceeded.
      For -7 or -9 models at ambient temperature TA = 85 °C with only
      convection cooling, and the maximum permissible current for each
      output is approx. 40% of its nominal value as per the figure below.
      Output Protection
      Each output is protected against overvoltages which could occur
      due to a failure of the internal control circuit. Voltage suppressor
      diodes (which under worst case condition may become a short
      circuit) provide the required protection. The suppressor diodes are
      not designed to withstand externally applied overvoltages.
      Overload at any of the outputs will cause a shut-down of all
      outputs. A red LED indicates the overload condition.
      Parallel or Series Connection
      Single or double-output models with equal nominal output voltage
      can be connected in parallel without any precautions using
      Option T (current sharing).
      Single output models and/or main and second outputs of double-
      output models can be connected in series with any other (similar)
      output.
      Notes:
      – Parallel connection of double output models should include both,
      main and second output to maintain good regulation of both
      outputs.
      – Not more than 5 models should be connected in parallel.
      – Series connection of second outputs without involving their main
      outputs should be avoided as regulation may be poor.
      – Rated output voltages above 36 V need additional measures in
      order to comply with the safety requirements for SELV (Safe Extra
      Low Voltage)
      – The maximum output current is limited by the output with the lowest
      current limitation if several outputs are connected in series.
      0
      0.1
      0.2
      0.3
      0.4
      0.5
      0.6
      0.7
      0.8
      50
      60
      70
      80
      90
      100
      Io/Io nom
      TA [C]
      0.9
      1.0
      Forced cooling
      05089_052305
      TA min
      TC max
      Convection cooling
      Fig. 7
      Output current derating versus temperature for -7 and -9
      models.
      Thermal Protection
      A temperature sensor generates an internal inhibit signal which
      disables the outputs if the case temperature exceeds TC max.
      The outputs are automatically re-enabled when the temperature
      drops below this limit.
      Continuous operation under simultaneous worst-case conditions
      of the following three parameters should be avoided: minimum
      input
      voltage,
      maximum
      output
      power,
      and
      maximum
      temperature.
      Output Voltage Regulation
      Fig. 8
      Output characteristic Vo1 vs. Io1 (typ.)
      Vo
      Vo nom
      0.98
      0.5
      0
      0.5
      1.0
      Io1
      IoL
      Io
      Io nom
      05098_050605
      The following figures apply to single-output or double-output
      models with parallel-connected outputs.
      相關(guān)PDF資料
      PDF描述
      FS2660-9RD1TB2 2-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
      FS1001-7ERV0TB1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
      FS1001-7RD8 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
      FS1001-9PD2 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
      FS1301-7EPD5B1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      FS-267 功能描述:ADAPTER JTAG ELAN486/386DRAM RoHS:是 類別:編程器,開發(fā)系統(tǒng) >> 配件 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program RoHS指令信息:IButton RoHS Compliance Plan 標準包裝:1 系列:- 附件類型:USB 至 1-Wire? RJ11 適配器 適用于相關(guān)產(chǎn)品:1-Wire? 設(shè)備 產(chǎn)品目錄頁面:1429 (CN2011-ZH PDF)
      FS2775-9RB1 制造商:MELCHER 功能描述: 制造商:Power-One 功能描述:
      FS28-040 功能描述:電源變壓器 1.1VA 28VCT @ 0.045A Dual Pri. 8 Pin RoHS:否 制造商:Triad Magnetics 功率額定值:12 VA 初級電壓額定值:115 V / 230 V 次級電壓額定值:12 V / 24 V 安裝風(fēng)格:SMD/SMT 一次繞組:Dual Primary Winding 二次繞組:Dual Secondary Winding 長度:2.5 in 寬度:2 in 高度:1.062 in
      FS28-040-C2 制造商:Triad Magnetics 功能描述:Transformer, class 2/3, 8-pin, 1.1VA, 115/230V x 28VCT at 0.04A, 14V at 0.08A
      FS28-040-C2-B 制造商:Triad Magnetics 功能描述:XFRMR LAMINATED 1.1VA THRU HOLE