S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
APR 26, 2006 revised to SEP 25, 2006
Page 5 of 33
www.power-one.com
Table 2b: Input data
Input
CS
DS
ES
LS
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
Vi
Operating input voltage
Io = 0 - Io nom
28
140
44
220
67
385
88
372
VDC
TC min - TC max
85
4
264
4
VAC
Vi nom Nominal input voltage
60
110
220
310
VDC
Ii
Input current
Vi nom, Io nom
1
2.1
1.1
0.55
0.4
A
Pi0
No-load input power
Vi min - Vi max
2.5
W
Pi inh
Idle input power
converter inhibited
1.5
4.5
Ri
Input resistance
150
170
180
480
m
Ω
RNTC
NTC resistance
2
12
4
Ω
Ci
Input capacitance
830
330
270
μF
Vi RFI
Conducted input RFI
EN 55022
B
Radiated input RFI
Vi nom, Io nom
BB
B
A
Vi abs
Input voltage limits
0
154
0
400
3
0
400
-400
400
VDC
without damage
1 For double output models both outputs loaded with I
o nom.
2 Valid for -7 versions without option E. This is the nominal value at 25 °C and applies to cold models at initial switch-on cycle. Subsequent
switch-on/off cycles increase the inrush current peak value.
3 For 1 s max.
4 AC operating frequency range is 47 to 440 Hz (440 Hz for 115 V mains). For frequencies
≥ 63 Hz refer to Safety and Installation Instructions.
Input Transient Protection
A suppressor diode and/or a VDR (depending on input voltage
range) together with the input fuse and a symmetrical input filter
form an effective protection against high input transient voltages
which typically occur in most installations, but especially in
battery-driven mobile applications.
Nominal battery voltages in use are: 12, 24, 36, 48, 60, 72, 110,
and 220 V. In most cases each nominal value is specified in a
tolerance of –30% to 25%.
In certain applications, surges according to RIA 12 are
specified in addition to those defined in IEC 60571-1. The
power supply must not switch off during these surges and
extremely wide input range is required. The ES input range
for 110 V batteries has been designed and tested to meet
this requirement.
Electrical Input Data
General Conditions
– TA = 25 °C, unless TC is specified.
– Pin 18 connected to pin 14, R input not connected, Vo adjusted to Vo nom (option P)
– Sense line pins S+ and S– connected to Vo+ and Vo–, respectively.
Table 2a: Input data
Input
AS
BS
FS
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
Unit
Vi
Operating input voltage
Io = 0 - Io nom
8
35
14
70
20
100
VDC
Vi nom Nominal input voltage
TC min - TC max
15
30
50
Ii
Input current
Vi nom, Io nom
1
7.5
4.3
2.6
A
Pi0
No-load input power
Vi min - Vi max
2.5
W
Pi inh
Idle input power
converter inhibited
1.5
Ri
Input resistance
65
100
70
m
Ω
Ci
Input capacitance
1040
370
1500
μF
Vi RFI Conducted input RFI
EN 55022
A
B
Radiated input RFI
Vi nom, Io nom
AAB
Vi abs Input voltage limits
0
40
0
80
0
100
VDC
without damage