IEC inlet lters
FN 380
Versatile ltered power entry module
Approvals
■
Rated currents up to 6A
■
Single or dual-fuse holder
■
Fuses 6.3 x 32mm or 5 x 20mm
■
2-pole rocker switch
■
General purpose application
■
Optional medical versions (B type)
Typical applications
The FN 380 power entry module combines an
IEC inlet, a mains filter with asingle or dual-
fuse holder and a 2-pole rocker switch.
Choosing FN 380 product line brings you the
rapid availability of a standard filter associated
with the necessary safety acceptances.
Standard IEC connector filters are a practi-
cal solution helping you to pass EMI system
approval in a short time. A wide selection on
amperage ratings, fuse options, mounting
possibilities and filters for medical applications
are designed to offer you the desired solution.
■
Good conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
■
Rear/front or snap-in mounting.
■
Single or dual-fuse holder.
■
USA 6.3 x 32mm or EU 5 x 20mm fuses.
■
2-pole rocker switch.
■
Voltage selector 110-120V / 220-240V.
■
Custom-specific versions are available on
request.
■
Portable electrical and electronic
equipment
■
Consumer goods
■
EDP and office equipment
■
Single-phase power supplies, switch-mode
power supplies
■
Test and measurement equipment
■
Medical equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage:
250VAC, 50/60Hz
Operating frequency:
50 to 400Hz
Rated currents:
1 to 6A @ 40°C max.
High potential test voltage:
P –> E 2000VAC for 2 sec (standard types)
P –> E 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
Protection category:
IP40 according to IEC 60529
Temperature range (operation and storage):
-25°C to +85°C (25/85/21)
Design corresponding to:
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to:
UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F):
550,000 hours
Rocker switch description:
Function:
2-pole, dark not illuminated
Marking I - 0
Electrical specifications:
Inrush current 51A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
Mechanical life:
50,000 cycles
Switch ratings:
USA (UL):
6A, 125VAC; 4A, 250VAC; 1/10HP
Canada (CSA):
6A, 125VAC; 4A, 250VAC; 1/10HP
Europe (ENEC):
6A (4A), 250VAC*
*
Value in () relates to the inductive current charge: cos γ = 0.65
Typical electrical schematic
N
E
P
Line
Cx
2xL
2xCy
Load
MK
H
LJ
G