PRODUCT SPECIFICATION
6
REV. 1.0.5 10/2/03
Comparator Mode
In Comparator Mode, each time a temperature-to-digital
(T-to-D) temperature conversion occurs, the new digital tem-
perature is compared to the value stored in the T
T
HYST
registers. If a fault tolerance number of consecutive
temperature measurements are greater than the value stored
in the T
OS
register, the O.S. output will be activated.
For example, if bits F1 and F0 are equal to “10” (fault
tolerance = 4), four consecutive temperature measurements
must exceed T
OS
to activate the O.S. output. Once the O.S
output is active, it will remain active until the first time the
measured temperature drops below the temperature stored in
the T
HYST
register. The operation of the alarm in Comparator
Mode with fault tolerance=2 is illustrated in Figure 1.
OS
and
Interrupt Mode
In Interrupt Mode the O.S. output will first become active
after a fault tolerance number of consecutive temperature
measurements exceed the value stored in the T
(similar to Comparator Mode). Once O.S. is active, it can
only be cleared by a user read from any of the FM75
registers (Temperature, Configuration, T
putting the FM75 into Shutdown Mode (i.e., by setting the
shutdown bit in the Configuration Register to “1”). Once
cleared, the O.S. output can only be activated the next time
by a fault tolerance number of consecutive temperature
measurements that are lower than the value stored in T
Again, once it is activated the O.S. output can only be
deactivated by a user read or shutdown. Thus, in Interrupt
Mode the activate/clear cycle for O.S. has the following
pattern: temperature > T
OS
, clear, temperature < T
clear, temperature > T
OS
, clear, etc. The operation of the
alarm in Interrupt Mode with fault tolerance=2 is also
illustrated in Figure 1.
OS
register
OS
, or T
HYST
) or by
HYST
.
HYST
,
Figure 1. Thermal Alarm Operation in Comparator and Interrupt Modes
For this example:
Fault Tolerance = 2
Output Polarity = Active Low
Read (or Shutdown)
T
OS
T
HYST
Temperature-to-Digital
Conversion
O.S. (Comparator Mode)
O.S. (Interrupt Mode)
相關(guān)PDF資料
PDF描述
FM803MS3X 3-Pin レC Supervisor Device
FM803RP3X 3-Pin レC Supervisor Device
FM803SP3X 3-Pin レC Supervisor Device
FM803TS3X 3-Pin レC Supervisor Device
FM803LP3X 3-Pin レC Supervisor Device
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
FM75MM8 功能描述:板上安裝溫度傳感器 Temp Sensor LV Digital I2C Comp RoHS:否 制造商:Omron Electronics 輸出類(lèi)型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
FM75MM8_Q 功能描述:板上安裝溫度傳感器 Temp Sensor LV Digital I2C Comp RoHS:否 制造商:Omron Electronics 輸出類(lèi)型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
FM75MM8X 功能描述:板上安裝溫度傳感器 Temp Sensor LV Digital I2C Comp RoHS:否 制造商:Omron Electronics 輸出類(lèi)型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
FM7C4 制造商:BACO Controls Inc 功能描述:
FM7Q1/25/W 制造商:Quam-Nichols Manufacturing 功能描述:6-1/2" O.D. LF speaker /1" HF, 2-way with multiple position "U" bracket, 20W-25V