Cassette Style
DC-DC Converters
M Series
Edition 01/01.2001
7/25
Electrical Output Data
General conditions
–
TA = 25
°C, unless T
C is specified.
– Connector pins 2 and 23 interconnected,
Uo = Uo nom (option P), R input not connected.
Table 4: Output data
Output
Uo nom
5.1 V
12 V
15 V
24 V
48 V
Characteristics
Conditions
min typ max
Unit
Uo
Output voltage
Ui nom, Io nom 1
5.07
5.13 11.93
12.07 14.91
15.09 23.86
24.14 47.72
48.28
V
Uo p
Output overvoltage
7.5
21
25
41
85
protection 6
Io nom Output current
Ui min...Ui max
see
Type Survey and Key Data
Output current
TC min...TC max
see Fig.
Typical output voltage Uo1 versus output currents Io
limitation response
uo
Output Switch. freq.
Ui nom, Io nom 1
15
30
25
50
35
70
40
80
50 100
mVpp
voltage
Total
IEC/EN 61204 5
60 120
40
80
40
80
40
80
-
noise
BW = 20 MHz
DUo U Static line regulation Ui min...Ui nom
±10 ±30
±12 ±50
±15 ±60
mV
Ui nom...Ui max
Io nom 1
DUo I Static load regulation Ui nom
6
25
1350
1760
3080
60 150
Io nom...0 2
DUo I c Static cross load
Ui nom
0
±15
0
±20
0
±30
0
±40
-
regulation 4
Io nom...0 3
uo d
Dynamic
Voltage
Ui nom
±220
±110
±150
±130
±150
load
deviation
Io nom
1/3 Io nom 2
td
regulation
Recovery
IEC/EN 61204
0.6
0.5
1
2
ms
time
uo d c Dynamic
Voltage
Ui nom
+10
+20
-
mV
cross load deviation
Io nom 1/3 Io nom 3
–100
–75
–140
–200
-
td c
regulation
Recovery
IEC/EN 61204
0.05
0.2
0.5
1
-
ms
4
time
0.5
0.3
0.7
2
-
aUo
Temperature
Ui min...Ui max
±0.02
%/K
coefficient
0...
Io nom
±1.0
±2.4
±3.0
±4.8
±9.6
mV/K
DUo/DTC
1 With multiple output modules, the same condition for each output applies.
2 Condition for specified output. With multiple output modules, other output(s) loaded with constant current Io nom. See fig.: Dynamic
load regulation.
3 Condition for non-specified output, individually tested, other output(s) loaded with constant current Io nom. See fig.: Dynamic load regu-
lation.
4 Multiple output modules.
5 See: Technical Information: Measuring and Testing.
6 By suppressor diode.