ELH0002H8837801301XX
Current Amplifier
Absolute Maximum Ratings (T
A
e
25 C)
VS
Supply Voltage
g
22V
VIN
Input Voltage
g
22V
PD
Power Dissipation Ambient
600 mW
TST
Storage Temperature
b
65 Cto a150 C
TA
Operating Temperature Range
ELH0002
b
55 Cto a125 C
Steady State Current
g
100 mA
Pulsed Output Current
(50 ms On1 second Off)
g
400 mA
Important Note
All parameters having MinMax specifications are guaranteed The Test Level column indicates the specific device testing actually
performed during production and Quality inspection Elantec performs most electrical tests using modern high-speed automatic test
equipment specifically the LTX77 Series system Unless otherwise noted all tests are pulsed tests therefore TJeTCeTA
Test Level
Test Procedure
I
100% production tested and QA sample tested per QA test plan QCX0002
II
100% production tested at TA e 25 C and QA sample tested at TA e 25 C
TMAX and TMIN per QA test plan QCX0002
III
QA sample tested per QA test plan QCX0002
IV
Parameter is guaranteed (but not tested) by Design and Characterization Data
V
Parameter is typical value at TA e 25 C for information purposes only
DC Electrical Characteristics V
S
e g
12V TMIN s TA s TMAX
Parameter
Description
Test Conditions
ELH0002
Units
Min
Typ
Max
Test
Level
VOS
Output Offset
RS e 300X RL e 1kX
g
10
g
30
I
mV
Voltage
AV
Voltage Gain
RS e 10 kX RL e 1kX
095
097
I
VV
VIN e g10 Vdc
RIN
Input Impedance
RS e 200 kX VIN e g1Vdc
180
400
I
k
X
RL e 1kX
ROUT
Output Impedance
RS e 50X VIN e g1Vdc
6
X
RS e 10 kX
VO
Output Voltage
VIN e g12V RL e 1KX
g
10
g
11
I
V
Swing
VS e g15V VIN e g12V
g
10
I
V
RS e 50X RL e 100X TA e 25 C
IB
Input Current
RS e 10 kX RL e 1kX
g
6
g
10
I
mA
ISa
Positive
RS e 10 kX RL e 1kX
610
I
mA
Supply Current
ISb
Negative
RS e 10 kX RL e 1kX
b
6
b
10
I
mA
Supply Current
Note 1 Elantec’s ELH0002H200 is tested to the ELH0002 DC limits at b25 C a25 C and a125 C and the AC limits at 25 C In
addition the parts are also tested to the DC limits for VOS AVOL with RL e 1kX IIN ISa and ISb at 200 C
2
TD
is
31in