DV200-27000S Series
DS15006F
2
SPECIFICATIONS (T
CASE = -55°C to +100°C, VIN = +270V ± 5%, Full Load, Unless Otherwise Specified)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
400 VDC
Junction Temperature Rise to Case
+25°C
Input Voltage (Transient, 1 second)
4
500 Volts
Storage Temperature
-65°C to +135°C
Output Power
1,2
175 Watts
Lead Solder Temperature (10 seconds)
270°C
Power Dissipation (Full Load, TCASE = +100°C)
40 Watts
Weight (Maximum)
115 Grams
DV200-2703R3S
DV200-27005S
Parameter
Conditions
Min
Typ
Max
Min
Typ
Max
Units
STATIC
Continuous
160
270
400
160
270
400
V
INPUT
Voltage
Transient, 1 sec
4
-
500
-
500
V
Inhibited
-
2
5
-
2
5
mA
Current
No Load
-
8
20
-
8
20
mA
Ripple Current
Full Load, 20Hz to 10MHz
-
100
150
-
100
175
mAp-p
Inhibit Pin Input
3
To Disable Output
0
-
1.5
0
-
1.5
V
Inhibit Pin Open Circuit Voltage
9.0
10.0
11.0
9.0
10.0
11.0
V
UVLO Turn On
140
150
159
140
150
159
V
UVLO Turn Off
3
135
140
150
135
140
150
V
VOUT
TCASE = 25°C
3.27
3.30
3.33
4.95
5.00
5.05
V
OUTPUT
Voltage
VOUT
TCASE = -55°C to +100°C
3.23
3.30
3.37
4.90
5.00
5.10
V
Power
2
0
-
100
0
-
150
W
Current
2
IOUT
0
-
30
0
-
30
A
Ripple Voltage
VOUT
Full Load, 10kHz to 10MHz
-
100
150
-
100
150
mVp-p
Line Regulation
VOUT
VIN = 160V to 400V
-
10
50
-
10
50
mV
Load Regulation
VOUT
No Load to Full Load
-
10
50
-
10
50
mV
Voltage Trim
VOUT
Full Load
-20
0
10
-20
-
10
%
EFFICIENCY
Full Load
75
79
-
80
83
-
%
Overload
3
-
30
-
30
-
W
LOAD FAULT POWER DISSIPATION
Short Circuit
3
-
30
-
30
-
W
CAPACITIVE LOAD
3
-
2000
-
2000
μF
SWITCHING FREQUENCY
400
500
600
400
500
600
kHz
SYNC FREQUENCY RANGE
VH – VL = 5V
Duty Cycle = 20% - 80%
450
500
550
450
500
550
kHz
ISOLATION
4
1000 VDC
100
-
100
-
M
MTBF (MIL-HDBK-217F)
GB @ TC = 55°C
-
955
-
955
-
kHrs
DYNAMIC
Load Step Output Transient
VOUT
-
200
400
-
200
400
mVPK
Load Step Recovery
5
Half Load to Full Load
-
200
300
-
200
300
μSec
Line Step Output Transient
3
VOUT
-
200
500
-
200
500
mVPK
Line Step Recovery
3, 5
VIN = 180V to 400V
-
100
200
-
100
200
μSec
Turn On Delay
VOUT
-
150
300
-
150
300
mSec
Turn On Overshoot
VIN = 0V to 270V
-
0
15
-
0
25
mVPK
Notes: 1. Dependant on output voltage. 2. Derate linearly to 0 at 110°C. 3. Verified by qualification testing. 4. Input to output and input to case.
Isolation from output to case is 500VDC. 5. Time for output voltage to settle within 1% of its nominal value.