DS1992/DS1993/DS1994
9 of 23
102199
Control Register
7
6
5
4
3
2
1
0
DSEL
STOP
START
AUTO
MAN.
OSC
RO
WPC
WPI
WPR
0201h
0
WPR
Write protect real-time clock/alarms registers
1
WPI
Write protect interval timer/alarms registers
2
WPC
Write protect cycle counter/alarms registers
Setting a write protect bit to a logic 1 will permanently write protect the corresponding counter and alarm
registers, all write protect bits, and additional bits in the control register. The write protect bits can not be
written in a normal manner (see “Write Protect/Programmable Expiration” section).
3
RO
Read only
If a programmable expiration occurs and the read only bit is set to a logic 1, then the DS1994 becomes
read only. If a programmable expiration occurs and the read only bit is a logic 0, then only the 64-bit
lasered ROM can be accessed (see “Write Protect/Programmable Expiration” section).
4
OSC
Oscillator enable
This bit controls the crystal oscillator. When set to a logic 1, the oscillator will start operation. When the
oscillator bit is a logic 0, the oscillator will stop.
5
AUTO/MAN
Automatic/Manual Mode
When this bit is set to a logic 1, the interval timer is in automatic mode. In this mode, the interval timer is
enabled by the data line. When this bit is set to a logic 0, the interval timer is in manual mode. In this
mode the interval timer is enabled by the STOP/START bit.
6
STOP/START
Stop/Start (in Manual Mode)
If the interval timer is in manual mode, the interval timer will start counting when this bit is set to a logic
0 and will stop counting when set to a logic 1. If the interval timer is in automatic mode, this bit has no
effect.
7
DSEL
Delay Select Bit
This bit selects the delay that it takes for the cycle counter and the interval timer (in auto mode) to see a
transition on the data line. When this bit is set to a logic 1, the delay time is 123
±2 ms. This delay allows
communication on the data line without starting or stopping the interval timer and without incrementing
the cycle counter. When this bit is set to a logic 0, the delay time is 3.5
±0.5 ms.