DFB01, PFB01
General Specifications
Power ON delay
Reaction time
1 s ± 0.5 s
(input signal variation from
-10% to +10% or from
+10% to -10% of the range)
< 200 ms
< 200 ms
(15 min warm-up time)
± 200 ppm/°C
± 10% on set value ±50 ms
± 0.02 Hz
Alarm ON delay
Alarm OFF delay
Accuracy
Temperature drift
Delay ON alarm
Repeatability
Indication for
Power supply ON
Alarm ON
LED, green
LED, red (flashing 2 Hz
during delay time)
LED, yellow
Output relay ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Housing dimensions
DIN-rail version
Plug-in version
Weight
Screw terminals
Tightening torque
IP 20
3 (DFB01), 2 (PFB01)
-20 to 60°C, R.H. < 95%
-30 to 80°C, R.H. < 95%
22.5 x 80 x 99.5 mm
36 x 80 x 94 mm
Approx. 150 g
Max. 0.5 Nm
acc. to IEC 60947
UL, CSA
Yes
Electromagnetic Compatibility
According to EN 61000-6-2
According to EN 61000-6-3
Approvals
CE-Marking
EMC
Immunity
Emission
Mode of Operation
DFB01 and PFB01 monitor
the frequency value of their
own power supply.
Example 1
(Non-latching mode - N.D.
relay)
The relay operates and the
yellow LED is ON as soon
as the measured frequency
exceeds the upper set level
or drops below the lower set
level for more than the set
delay time. The relay releas-
es when the measured fre-
quency comes back within
the upper and lower limits.
The red LED flashes until the
delay time has expired or
the measured value falls off
the limits.
Example 2
(Latching mode - N.E. relay)
The relay operates and the
yellow LED is ON as long as
the measured frequency is
within the upper and lower
limits.
The
relay
releases
latches in alarm position as
soon as the measured fre-
quency exceeds the upper
set level or drops below the
lower set level for more than
the set delay time. The red
LED flashes until the delay
time has expired or the
measured value comes back
within the limits. Provided
that
the
frequency
dropped below the upper
set level (minus hysteresis)
or exceeded the lower set
level (plus hysteresis), the
relay operates when the
interconnections
terminals Z1, Z2 or 8, 9 are
interrupted.
and
has
between
Supply Specifications
Power supply
Rated operational voltage
Through terminals:
Overvoltage cat. III
(IEC 60664, IEC 60038)
DFB01: A1, A2
PFB01:
24 to 240 VAC ± 15%
24 to 240 VAC ± 15%
2,10
Dielectric voltage
Supply to output
Rated operational power
4 kV
4 W
Adjust the system frequency
setting DIP switch 3 and
select the desired function
setting the DIP switches 1, 2
and 4 as shown on the right.
To access the DIP switches
open the grey plastic cover
as shown on the right.
Selection of level and time
delay:
Upper knob:
Setting of upper level:
-10 to +100% of the range.
Centre knob:
Setting of lower level:
-100 to +10% of the range.
Lower knob:
Setting of delay on alarm
time: 0.1 to 30 s.
Function/Range/Level and Time Delay Setting
Setpoint range
ON: 2 Hz
OFF: 10 Hz
Relay working mode
ON: Normally De-Energized
OFF: Normally Energized
Contact input
ON: Lacth function enable
OFF: Inhibit function enable
System frequency
ON: 60 Hz
OFF: 50 Hz