3
DCP0105
SPECIFICATIONS
(CONT)
At T
A
= +25
°
C, V
S
= +5V, unless otherwise specified.
DCP0105 SERIES
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
GENERAL (Cont)
Efficiency
DCP010505P
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
T
A
= +85
°
C
T
A
= +55
°
C
T
A
= +25
°
C
14-Pin PDIP
71
40
66
47
72
38
72
36
73
40
75
38
%
%
%
%
%
%
%
%
%
%
%
%
hrs
hrs
hrs
DCP010505DP
DCP010512P
DCP010512DP
DCP010515P
DCP010515DP
MTTF
(3)
158,000
3,050,000
108,000,000
Weight
1.08
g
THERMAL SHUTDOWN
Internal Controller IC Temperature
Shutdown Current
115
140
°
C
mA
3
TEMPERATURE RANGE
Operating
–40
+100
°
C
NOTES: (1) 100% load current = 1W/V
NOM
typical. (2) Rated working voltage = 130Vrms (IEC950 Convention). (3) Life test data.
EMC SPECIFICATIONS
Specifications and Related Documents
The DCP010505P was tested to and complied with the limits of the following EMC specifications:
prEN55022 (1992)
Conducted RF emission, telecomm lines.
EN55022 (1995)
Limits and methods of measurement of radio interference characteristics of information technology equipment.
ENV50140 (1993)
Electromagnetic compatibility. Basic immunity standard. Radiated RF immunity.
ENV50141 (1993)
Electromagnetic compatibility. Basic immunity standard. Conducted RF immunity.
EN61000-4-2 (1995)
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 2. Electrostatic
discharge.
EN61000-4-4 (1995)
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 4. Electrical fast
transient bursts.
EN61000-4-8 (1994)
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 8. Power frequency
magnetic field immunity.
List of Tests
The following is a list of tests which were required for compliance with the above specifications:
Conducted Emission Test
150kHz to 30MHz, power and output lines, Class B limits applying. DC/DC loads of
0%, 8%, and 120% applying.
Radiated Emission Test
30MHz to 1000MHz, Class B limits applying. DC/DC loads of 0%, 8%, and 120%
applying.
Radiated Immunity Test, Electric Field
80MHz to 1000MHz, 10V/m, 1kHz 80% AM.
Radiated Immunity Test, Electric Field
900MHz, 10V/m, 200Hz 100% PM.
Electrostatic Discharge Test
4kV, HCP/VCP indirect discharge only.
Electrical Fast Transient Tests
2kV power lines, 2kV signal lines.
Conducted RF Immunity Tests
150kHz to 80MHz, power and output lines, 10Vrms, 1kHz 80% AM.
Radiated Immunity Test, Magnetic Field
50Hz, 30A/m