CLP270M
13/24
Asshownonthesefigures,themaximumremainingvoltagedoesnotexceed+8.5Vforpositivesurgesand
-65V for negative surges.
2/10 μs
GENERATOR
+/- 5 kV
(500 A)
4
TIPL
TIPS
GND
1/2 CLP270M
I
V1
1
Rsense
Rp
Fig. 16:
Lightning test in Ringing mode.
Fig. 17:
CLP270M response to a positive surge.
Fig. 18:
CLP270M response to a negative surge.
3.3. Second level lightning surge
3.3.1. Lightning test in ringing mode