7-1252
Specifications CD4555BMS, CD4556BMS
Propagation Delay
A or B Input to any Output
TPHL1
TPLH1
VDD = 10V
1, 2, 3
+25
o
C
+25
o
C
+25
o
C
+25
o
C
+25
o
C
+25
o
C
+25
o
C
-
190
ns
VDD = 15V
1, 2, 3
-
140
ns
Propagation Delay
E to any Output
TPHL2
TPLH2
VDD = 10V
1, 2, 3
-
170
ns
VDD = 15V
1, 2, 3
-
130
ns
Transition Time
TTHL
TTLH
VDD = 10V
1, 2, 3
-
100
ns
VDD = 15V
1, 2, 3
-
80
ns
Input Capacitance
CIN
Any Input
1, 2
-
7.5
pF
NOTES:
1. All voltages referenced to device GND.
2. The parameters listed on Table 3 are controlled via design or process and are not directly tested. These parameters are characterized
on initial design release and upon design changes which would affect these characteristics.
3. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
TABLE 4. POST IRRADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS
PARAMETER
SYMBOL
CONDITIONS
NOTES
TEMPERATURE
+25
o
C
+25
o
C
+25
o
C
LIMITS
UNITS
MIN
MAX
Supply Current
IDD
VDD = 20V, VIN = VDD or GND
1, 4
-
25
μ
A
N Threshold Voltage
VNTH
VDD = 10V, ISS = -10
μ
A
1, 4
-2.8
-0.2
V
N Threshold Voltage
Delta
VTN
VDD = 10V, ISS = -10
μ
A
1, 4
-
±
1
V
P Threshold Voltage
VTP
VSS = 0V, IDD = 10
μ
A
1, 4
+25
o
C
+25
o
C
0.2
2.8
V
P Threshold Voltage
Delta
VTP
VSS = 0V, IDD = 10
μ
A
1, 4
-
±
1
V
Functional
F
VDD = 18V, VIN = VDD or GND
1
+25
o
C
VOH >
VDD/2
VOL <
VDD/2
V
VDD = 3V, VIN = VDD or GND
Propagation Delay Time
TPHL
TPLH
VDD = 5V
1, 2, 3, 4
+25
o
C
-
1.35 x
+25
o
C
Limit
ns
NOTES: 1. All voltages referenced to device GND.
2. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
3. See Table 2 for +25
o
C limit.
4. Read and Record
TABLE 5. BURN-IN AND LIFE TEST DELTA PARAMETERS +25
o
C
PARAMETER
SYMBOL
DELTA LIMIT
Supply Current - MSI-2
IDD
±
1.0
μ
A
Output Current (Sink)
IOL5
±
20% x Pre-Test Reading
Output Current (Source)
IOH5A
±
20% x Pre-Test Reading
TABLE 6. APPLICABLE SUBGROUPS
CONFORMANCE GROUP
Initial Test (Pre Burn-In)
Interim Test 1 (Post Burn-In)
Interim Test 2 (Post Burn-In)
PDA (Note 1)
Interim Test 3 (Post Burn-In)
PDA (Note 1)
MIL-STD-883
METHOD
100% 5004
100% 5004
100% 5004
100% 5004
100% 5004
100% 5004
GROUP A SUBGROUPS
1, 7, 9
1, 7, 9
1, 7, 9
1, 7, 9, Deltas
1, 7, 9
1, 7, 9, Deltas
READ AND RECORD
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
TABLE 3. ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
PARAMETER
SYMBOL
CONDITIONS
NOTES
TEMPERATURE
LIMITS
UNITS
MIN
MAX