World Modem NET Page 21 of 64 2005 Copeland Communications, Inc. World Modem NET Datasheet Rev 1.0 Basic AT Command Set (Command Defau" />
參數(shù)資料
型號: CC-93K2N-CS5
廠商: Copeland Communications Inc
文件頁數(shù): 14/64頁
文件大?。?/td> 0K
描述: MODEM 56KBAUD SERIAL V.92 5V
標(biāo)準(zhǔn)包裝: 30
數(shù)據(jù)格式: V.22,V23,V.32,V.34,V.90,V.92,Bell 103,Bell 212A
波特率: 56k
電源電壓: 4.2 V ~ 7 V
安裝類型: 表面貼裝
封裝/外殼: 模塊
包裝: 散裝
其它名稱: 539-1013
CC-92K2N-CS5
Data Sheet
World Modem NET
Page 21 of 64
2005 Copeland Communications, Inc.
World Modem NET Datasheet Rev 1.0
Basic AT Command Set (Command Defaults in Bold) (Continued)
Command
Action
+IFC Options
Specifies the flow control to be implemented.
+IFC = A
A
Specifies the flow control method used by the host to control data from the modem.
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remot modem.
2 Hardware flow control (RTS).
B
Specifies the flow control method used by the modem to control data from the host.
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remot modem.
+IFC = A,B
2 Hardware flow control (CTS).
+ITF Options
Transmit flow control threshold.
+ITF = A
A
Threshold above which the modem will generate a flow off signal.
+ITF = A,B
< 0 to 511> bytes
B
Threshold below which the modem will generate a flow on signal
< 0 to 511> bytes
C
Polling interval for <EM><BNUM> indicator
+ITF = A,B,C
0 to 300 in 10 msec units.
Modulation reporting control.
X
Mode
0
Disabled
1
Enabled
If enabled, the intermediate result code is transmitted at the point during connect negotiation. The
format of this result code is asw follows:
+MCR: <carrier> e.g. +MCR: V32B
+MR = X
+MRR: <rate> e.g. +MRR: 14400
+MS Options
Modulation Selection.
+MS = A
A
Preferred modem carrier
+MS = A,B
V21
ITU-T V.21
+MS = A,B,C
V22
ITU-T V.22
+MS = A,B,C,D
V.22B
ITU-T V.22bis
+MS = A,B,C,D,E
V32
ITU-T V.32 (default for CC-14.4K2)
V.32B
ITU-T V.32bis
V34
ITU-T V.34 (default for CC-33K2)
V90
ITU-T V.90 (default for CC-56K2)
B
Automatic modulation negotiation
0
Disabled
1
Enabled
C,D Min rate/Min rx rate are optional numeric values that specify the lowest value at which the
DCE ma establish a connection. If unspecified (set to zero), the are determined by the carrier and
automode settings.
+MS =
A,B,C,D,E,F
E,F Max rate/Max rx rate are optional numeric values which specify the highest values which
specify the highest value at which the DCE may establish a connection. If unspecified (set to 0),
they are determined by the carrier and automode settings.
相關(guān)PDF資料
PDF描述
CC-56K2N-CS5 MODEM 56KBAUD SERIAL 5V
CC-2404K2N-CS5 MODEM 2400BAUD SERIAL 5V
SI3015-BS IC ISOMODEM LINE-SIDE DAA 16SOIC
PIC16C54T-XTE/SO IC MCU OTP 512X12 18SOIC
PIC16C54T-RC/SS IC MCU OTP 512X12 20SSOP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CC94.0 制造商:Schneider Electric 功能描述:THERMAL UNIT
CC9418P 制造商:Honeywell Sensing and Control 功能描述:
CC9418S 制造商:Honeywell Sensing and Control 功能描述:
CC-9604C 制造商:Ameba Technology Inc 功能描述:Board and Mini Case Cameras Sony 1-3 Super Had CCD Sensor an
CC-9801166-1250' 制造商:DigitHead Inc 功能描述:1250'CUSTOM ALPHA CABLE#6032C, PER DRAWING 9801166B