HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Hamamatsu City, 435-8558 Japan, Telephone: (81) 053-434-3311, Fax: (81) 053-434-5184, http://www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658
France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Smidesvgen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741
2
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. 2002 Hamamatsu Photonics K.K.
Photosensor amplifier
C9051
Cat. No. KACC1080E01
Aug. 2002 DN
(85 ± 3)
OUTPUT
TERMINAL
PHOTODIODE PHOTOCURRENT
INPUT TERMINAL
(4
×
) 3.2 THRU-HOLE
(FOR BOARD MOUNTING)
AC ADAPTER JACK DC + 12 V IN
4
(
2
5
50 ± 1
42 ± 0.5
OUT
IN
KACCA0116EA
I
Connection example
I
Dimensional outline (unit: mm)
KACCC0179EA
PHOTOSENSOR AMPLIFIER C9051
COAXIAL CABLE WITH BNC PLUG
(See "Typical connection to photodiode")
LARGE AREA PHOTODIODE
DC + 12 V
BNC-BNC
COAXIAL CABLE
OSCILLOSCOPE
VOLTMETER
LOW-LIGHT-LEVEL
OPTICAL POWER METERS
DC LIGHT MONITORS
TEST/MEASUREMENT
EQUIPMENT
LOW-LIGHT-LEVEL
DETECTION
+ 5 V INPUT A/D
SERIAL CONVERSION
OUTPUT
PC, etc.
ANODE
CATHODE
SHIELD
ANODE
PHOTODIODE
SHIELD CASE, etc.
CONNECT TO SHIELD CASE
SOLDER
COAXIAL CABLE WITH BNC PLUG
CATHODE
KACCC0180EA
I
Accessory
AC adapter
I
Typical connection to photodiode
To connect a photodiode to C9051, use a coaxial cable terminated with a
BNC plug. The cable length (capacitance) should be less than 15 nF
including photodiode terminal capacitance.
Solder the photodiode leads to connect the tip of the cable wire. (See the
drawing on the right.)
Anode: Connect to the shield wire of the cable. (Make electrical connection
with the shield.)
Cathode: Connect to the core wire of the cable.
To improve measurement accuracy, provide a shield around the photodiode.
Do not use a cable any longer than necessary. (Keep the cable as short as
possible.)
NOTE) When using a photodiode whose cathode is internally connected to its
metal package, secure the photodiode with an insulating material
when shielding. Otherwise, signal current cannot be drawn when the
photodiode package is grounded.