General
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Isolation Resistance - Input to Output
Isolation Capacitance - Input to Output
No Load Input Power
Case Temperature
Standard Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Safety
Weight (approx.)
200 kHz
500 VDC
500 VDC
500 VDC
109 Ohms
80 pF
0.70 W
-25 to +85°C
-40 to +125°C
95%
5 g, 10 - 55 Hz
UL, cUL, TUV
0.6 oz
1
1Continuous short circuit protection is provided. Long-term continuous
operation in this mode is not recommended. Converter will auto-restart
once fault has been removed.
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Setpoint Accuracy
Line Regulation Vin Min. - VinMax., IoutRated
Load Regulation IoutMin. - IoutMax., VinNom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Temperature Coefficient
Ripple And Noise, 20 MHz BW
Short Circuit Protection 1
Current Limit
±5%
±1.5% Vout
±2.5% Vout
10% Iout Rated
25% Iout
1% Vout
500 ms
0.02%/°C
150 mV
Continuous
180%
Output
Voltage Range
5 VDC Nominal
12 VDC Nominal
4.5 - 9 VDC
9 - 18 VDC
20% Iin Max.
100% IinMax.
Reflected Ripple
Reverse Input Current
TECHNICAL SPECIFICATIONS
BWS DC/DC converters offer excellent regulation and
isolation in an industry-standard DIP package. The BWS
is ideal for industrial, telecom, and networking
applications, and features short circuit protection, low
profile, and 500 VDC isolation. Please see the BWD series
for dual output applications.
Industry Standard DIP
Package
Industry Standard Pinout
85°C Case Operation
Short Circuit Protection
Wide Range Inputs
Input Pi Filter
Regulated Outputs
500V Isolation
Input
DESCRIPTION
FEATURES
BWS SERIES - 2.5 WATT
Notes