      參數(shù)資料
      型號: BUS-65143-410Q
      英文描述: Transil™
      中文描述: MIL-STD-1553/ARINC總線控制器/ RTU通訊
      文件頁數(shù): 7/24頁
      文件大小: 219K
      代理商: BUS-65143-410Q
      第1頁第2頁第3頁第4頁第5頁第6頁當前第7頁第8頁第9頁第10頁第11頁第12頁第13頁第14頁第15頁第16頁第17頁第18頁第19頁第20頁第21頁第22頁第23頁第24頁
      15
      RESERVED MODE COMMAND (01001-01111)
      MESSAGE SEQUENCE = RESERVED MODE COMMAND * STATUS
      The RTU responds with clear status and no data. If the command is illegalized through an optional PROM, the message error bit is set and only
      the ststus word is transmitted.
      ERROR CONDITIONS
      1. Invalid Command. No response, command ignored.
      2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word).
      3.
      bit Set to Zero. No statue response. Bits set: message error (S/W), Illegal Mode Code (BIT Word).
      4. Zero
      bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code (BIT Word).
      R
      T/
      R
      T/
      RESET REMOTE TERMINAL (01000)
      MESSAGE SEQUENCE = RESET REMOTE TERMINAL * STATUS
      The RTU responds with status and internally reseets. Transmitter shutdown, mode commands, BIT Word, and inhibit terminal flag commands will
      be reseet. If the command was broadcast, the broadcast received bit is set and the status word is suppressed.
      ERROR CONDITIONS
      1. Invalid Command. No response, command ignored.
      2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word).
      3.
      bit Set to Zero. No statue response. Bits Set: message error (S/W), T/R Error (BIT Word).
      4. Zero
      bit and Broadcast Address. No statue response.. Bits set: message error, broadcast received (S/W), T/R Error (BIT Word).
      R
      T/
      R
      T/
      OVERRIDE INHIBIT TERMINAL FLAG BIT (00111)
      MESSAGE SEQUENCE = OVERRIDE INHIBIT TERMINAL FLAG * STATUS
      The RTU responds with status and reactivates the terminal flag bit in the status register. If the command was broadcast, the broadcast received bit
      is set and and status transmission is suppressed.
      ERROR CONDITIONS
      1. Invalid Command. No response, command ignored.
      2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
      3.
      bit Set to Zero. No statue response. Bits set: message error (S/W), T/R Error (BIT Word).
      4. Zero
      bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), T/R Error (BIT Word).
      R
      T/
      R
      T/
      INHIBIT TERMINAL FLAG BIT (00110)
      MESSAGE SEQUENCE = INHIBIT TERMINAL FLAG * STATUS
      The RTU responds with status and inhibits further internal or external setting of the terminal flag bit in the status register. Once the terminal flag
      has been inhibited, it can only be reactivated by an Override Inhibit Terminal Flag or Reset RT command. If the command was broadcast, the
      broadcast received bit is set and status transmission is suppressed.
      ERROR CONDITIONS
      1. Invalid Command. No response, command ignored.
      2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
      3.
      bit Set to Zero. No statue response. Bits set: message error (S/W), T/R Error (BIT Word).
      4. Zero
      bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), T/R Error (BIT Word).
      R
      T/
      R
      T/
      OVERRIDE TRANSMITTER SHUTDOWN (00101)
      MESSAGE SEQUENCE = OVERRIDE SHUTDOWN * STATUS
      This command is only used with dual redundant bus systems. The RTU responds with status. At the end of the status transmission, the RTU re-
      enables the transmitter of the redundant bus. If the command was broadcast, the broadcast received bit is set and status transmission is sup-
      pressed.
      ERROR CONDITIONS
      1. Invalid Command. No response, command ignored.
      2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
      3.
      bit Set to Zero. No statue response. Bits set: message error, broadcast received (S/W), T/R Error (BIT Word).
      4. Zero
      bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code,
      T/R Error (BIT Word).
      R
      T/
      R
      T/
      TABLE 2. MODE CODES IMPLEMENTED (continued)
      * = Status Response Time
      相關PDF資料
      PDF描述
      BUS-65143-410S Transil™
      BUS-65143-410W Transil™
      BUS-65143-410Y Transil™
      BUS-65143-410Z Transil™
      BUS-65143-420 Transil™
      相關代理商/技術參數(shù)
      參數(shù)描述
      BU-S802 制造商:Fuji Electric 功能描述:
      BU-S803 制造商:Fuji Electric 功能描述:
      BUS98 制造商:ONSEMI 制造商全稱:ON Semiconductor 功能描述:SITCHMODE Series NPN Silicon Power Transistors
      BUS98/D 制造商:未知廠家 制造商全稱:未知廠家 功能描述:SWITCHMODE? Series NPN Silicon Power Transistors
      BUS98A 制造商:ONSEMI 制造商全稱:ON Semiconductor 功能描述:SITCHMODE Series NPN Silicon Power Transistors
      發(fā)布緊急采購,3分鐘左右您將得到回復。

      采購需求

      (若只采購一條型號,填寫一行即可)

      發(fā)布成功!您可以繼續(xù)發(fā)布采購。也可以進入我的后臺,查看報價

      發(fā)布成功!您可以繼續(xù)發(fā)布采購。也可以進入我的后臺,查看報價

      *型號 *數(shù)量 廠商 批號 封裝
      添加更多采購

      我的聯(lián)系方式

      *
      *
      *
      • VIP會員服務 |
      • 廣告服務 |
      • 付款方式 |
      • 聯(lián)系我們 |
      • 招聘銷售 |
      • 免責條款 |
      • 網(wǎng)站地圖

      感谢您访问我们的网站,您可能还对以下资源感兴趣:

      三级特黄60分钟在线观看,美女在线永久免费网站,边吃奶边摸下很爽视频,娇妻在厨房被朋友玩得呻吟`