• <var id="be4zj"></var>
    參數(shù)資料
    型號: BU-61559
    英文描述: MIL-STD-1553 Components |AIM-HY'er
    中文描述: 符合MIL - STD - 1553器件|枚AIM - HY\u0026#39;er
    文件頁數(shù): 14/32頁
    文件大?。?/td> 833K
    代理商: BU-61559
    14
    Data Device Corporation
    www.ddc-web.com
    BU-61559 Series
    C-12/02-300
    In RT mode, the host processor may determine that a message
    has been processed either by means of interrupts or by polling
    the Interrupt Status Register or the Stack Pointer.
    The Stack Pointer increments by four (modulo 256) during the
    Start-of-Message sequence for each message processed. After
    processing a message, the host CPU should read the Block
    Status Word, Time Tag, data block starting address, and
    Command Word received from the Message Block Descriptor in
    the Stack. Assuming a valid message was received, it may then
    read the received data from the respective data block.
    The BU-61559 offers a great deal of flexibility in terms of RT
    interrupt processing. In some systems, the transmission or
    reception of a message with a particular subaddress denotes the
    end of a complete set of consistent data. In this instance, the
    user should use the RT SUBADDRESS CONTROL WORD
    INTERRUPT in order to issue an interrupt request
    only for a
    particular T/R-subaddress
    , rather than following every mes-
    sage. One technique would then be for the host processor to
    switch the active area of shared RAM, by toggling bit 13 of
    Configuration Register #1 at this time.This allows the next group
    of messages comprising a consistent data set to be stored in the
    alternate area of the shared RAM address space.
    IMPLEMENTING BULK DATA TRANSFERS
    In systems involving bulk data transfers over the 1553 bus
    to/from the same subaddress, the host CPU should set the
    OVERWRITE INVALID DATA bit (bit 11) of Configuration
    Register #2 and enable the RT CIRCULAR BUFFER
    ROLLOVER interrupt request.By doing so, the routine transfer of
    multiple messages to the selected subaddress,
    including errors
    and retries
    , is transparent to the host processor.The BU-61559
    will issue an interrupt request only after it has received the antic-
    ipated number of
    valid
    data words to the particular subaddress.
    The anticipated number of words to be received (or transmitted)
    is programmable up to 8192 words.
    RT COMMAND ILLEGALIZATION
    The BU-61559 provides an internal mechanism for RT
    Command Word illegalizing. The scheme utilizes a 256-word
    area in the BU-61559's internal dual port RAM. A benefit of this
    feature is reduced printed circuit board space requirements, by
    eliminating the need for an external PROM, PLD, or RAM device
    to perform the illegalizing function.The BU-61559's illegalization
    scheme provides the maximum in flexibility, allowing any subset
    of the 4096 possible combinations of broadcast/own address,
    T/R bit, subaddress, and word count/mode code to be illegalized.
    Another advantage of the RAM-based illegalization scheme is
    that it is inherently self-testable.
    In order to use the BU-61559's internal dual port RAM for RT
    command illegalizing, it is necessary to connect the input signal
    ILLENA to logic 1. By so doing, address locations 0300 through
    03FF are dedicated for the message illegalizing function and
    must not
    be used for Stack or Data Block storage.The RT com-
    mand illegalization option may be disabled by connecting
    ILLENA to logic 0. In this instance, the BU-61559 assumes all
    received Command Words are legal. If ILLENA is connected to
    logic 0, address locations 0300 through 03FF may be used for
    the storage of Stacks or Data Blocks.
    It should be noted that the state of the ILLENA input has
    no
    effect
    for BC or Monitor (MT) modes.
    If the command illegalizing feature is used, address locations
    0300-03FF
    must
    be mapped to the respective locations in the
    BU-61559's 8K X 16 of
    internal
    shared RAM.
    ADDRESSING THE ILLEGALIZATION TABLE
    The addressing scheme of the illegalization RAM is illustrated by
    FIGURE 16.As shown, the base address of the illegalizing RAM is
    0300 (hex). The index into the illegalizing RAM is formulated by
    means of BROADCAST/OWN ADDRESS, T/R bit, Subaddress,
    and the MSB of the Word Count/Mode Code field (WC/MC4).
    The internal RAM has 256 words reserved for command illegal-
    ization. Broadcast commands may be illegalized separately from
    non-broadcast receive commands and mode commands.
    Commands may be illegalized down to the word count level. For
    example, a one-word receive command to subaddress 1 may be
    legal, while a 2-word receive command to subaddress 1 may be
    illegalized.
    The first 64 words of the Illegalization Table refer to broadcast
    receive commands (two words per subaddress). The next 64
    words refer to broadcast transmit commands. Since non-mode
    code broadcast transmit commands are by definition invalid, this
    section of the table (except for subaddresses 0 and 31) does
    not
    need to be initialized by the user.The next 64 words correspond
    to non-broadcast receive commands.The final 64 words refer to
    non-broadcast transmit commands. Messages with Word Count/
    Mode Code (WC/MC) fields between 0 and 15 may be illegalized
    by setting the corresponding data bits for the respective even-
    numbered address locations in the illegalization table. Likewise,
    messages with WC/MC fields between 16 and 31 may be illegal-
    ized by setting the corresponding data bits for the respective
    odd-numbered address locations in the illegalization table.
    The following should be noted with regards to command illegal-
    ization:
    (1) To illegalize a particular word count for a given broadcast/own
    address-T/R subaddress, the appropriate bit position in the
    respective illegalization word should be set to logic 1. A bit
    value of logic 0 designates the respective Command Word as
    a legal command. The BU-61559 will respond to an illegal-
    ized non-broadcast command with the Message Error bit set
    in its RT Status Word.
    相關(guān)PDF資料
    PDF描述
    BU-61585 MIL-STD-1553 Components |ACE
    BU61585S3-122 MIL-STD-1553/ARINC Bus Controller/RTU
    BU61585S6-100 MIL-STD-1553/ARINC Bus Controller/RTU
    BU61585S6-110 MIL-STD-1553/ARINC Bus Controller/RTU
    BU61585S6-120 MIL-STD-1553/ARINC Bus Controller/RTU
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    BU-61580 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553 Components |ACE
    BU-61580G1-100 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61580G1-110 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61580G1-120 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61580G1-200 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU