BP5039-12 / BP5039-15 / BP5039A
Power Module
!
Electrical characteristics
(unless otherwise noted, Ta = 25
°
C)
BP5039-12
Parameter
Symbol
Unit
Conditions
Min.
Typ.
Max.
Input voltage
V
IN
113
141
170
V
Output voltage
V
O
11
12
13
V
Output current
I
O
0
300
mA
Line regulation
Vr
0.10
0.04
+
0.10
V
V
IN
=
113V~170V, I
O
=
100mA
Load regulation
Vl
0.20
0.05
+
0.20
V
Output ripple voltage
0.07
0.15
V
PP
Conversion efficiency
1 Maximum output current varies depending on ambient temperature; please refer to derating curve.
2 Spike noise is not included in output ripple voltage.
η
65
74
%
Vp
V
IN
=
141V, I
O
=
100mA
V
IN
=
141V, I
O
=
300mA
V
IN
=
141V, I
O
=
100mA
V
IN
=
141V, I
O
=
0~100mA
V
IN
=
141V
1
2
DC
BP5039-15
1 Maximum output current varies depending on ambient temperature; please refer to derating curve.
2 Spike noise is not included in output ripple voltage.
Parameter
Symbol
Unit
Conditions
Min.
Typ.
Max.
Input voltage
V
IN
113
141
170
V
Output voltage
V
O
14.25
15.0
15.75
V
Output current
I
O
0
200
mA
Line regulation
Vr
0.20
0.05
+
0.20
V
V
IN
=
141V, I
O
=
0~100mA
Load regulation
Vl
0.20
0.05
+
0.20
V
Output ripple voltage
0.07
0.15
V
PP
Conversion efficiency
η
60
74
%
Vp
V
IN
=
141V
1
2
V
IN
=
141V, I
O
=
200mA
Surface temperature rise
Tc
38
K
V
IN
=
141V, I
O
=
200mA
V
IN
=
141V, I
O
=
200mA
V
IN
=
141V, I
O
=
100mA
V
IN
=
113V~170V, I
O
=
100mA
DC
BA5039A
1 Maximum output current varies depending on ambient temperature; please refer to derating curve.
2 Spike noise is not included in output ripple voltage.
Parameter
Symbol
Unit
Conditions
Min.
Typ.
Max.
Input voltage
113
141
170
V
Output voltage
V
O
22
24
26
V
Output current
I
O
0
200
mA
Line regulation
Vr
0.15
0.04
+
0.15
V
Load regulation
Vl
0.50
0.25
+
0.50
V
Output ripple voltage
0.07
V
PP
Conversion efficiency
η
70
82
%
Vp
V
IN
=
141V
V
IN
=
113V~170V, I
O
=
100mA
1
2
V
IN
=
141V, I
O
=
200mA
V
IN
=
141V, I
O
=
0~
+
100mA
V
IN
=
141V, I
O
=
100mA
V
IN
=
141V, I
O
=
100mA
DC
Spike noise
Ripple
V
IN