N/AL.
8.240.
300.02
1/97
Typical Performance Characteristics
B64G
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
FLOW CHARACTERISTICS
0
20
40
60
80
100
dm
3
/s
AIR FLOW
0
40
80
120
160
200
240 scfm
8
6
4
2
0
O
100
80
60
40
20
0
PORT SIZE: 1/2"
INLET PRESSURE: 10 bar (145 psig)
RANGE: 0,3 to 10 bar (5 to 145 psig)
40
μ
m ELEMENT
Ordering Information.
Models listed include ISO G threads, knob adjustment, automatic drain, metal bowl, 40 μm element, relieving
diaphragm and 0,3 to 10 bar (5 to 145 psig) outlet pressure adjustment range* without gauge.
Typical flow with 10 bar (145 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (15 psig) droop from set.
Port Size
G1/4
G3/8
G1/2
G3/4
Model
B64G-2GK-AD3-RMN
B64G-3GK-AD3-RMN
B64G-4GK-AD3-RMN
B64G-6GK-AD3-RMN
Flow
dm
3
/s (scfm)
30 (64)
76 (161)
106 (225)
N.A.
Weight kg (lb)
1,71 (3.80)
1,69 (3.76)
1,66 (3.69)
2,02 (4.49)
Alternative Models
B 6 4
-
G
# #
-
#
#
#
#
Port Size
1/4"
3/8"
1/2"
3/4"
Substitute
2
3
4
6
Threads
PTF
ISO Rc taper
ISO G parallel
Substitute
A
B
G
Diaphragm
Relieving
Non relieving
Substitute
R
N
Element
5 μm
25 μm
40 μm
Substitute
1
2
3
Adjustment
Knob
T-bar
Substitute
K
T
Bowl
Metal with liquid level indicator
Guarded Transparent
Substitute
D
P
-
#
#
#
Drain
1/4 turn manual
Automatic
Substitute
M
A
Gauge
With
Without
Substitute
G
N
Outlet Pressure Adjustment Range*
0,3 to 4 bar (5 to 60 psig)
0,3 to 10 bar (5 to 145 psig)
2 to 17 bar (29 to 250 psig)
Substitute
F
M
S**
*
Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
Units with 17 bar (250 psig) adjustment
range are available only with the T-bar
adjustment; therefore substitute
T
at the 7th
digit and
S
at the 12th position.
**