2000-06-06
ZETTLER
electronics
Logistic Design (UK) Limited. Unit 3, Eagle Centre Way, Luton LU4 9US www.zettlerrelay.com sales@zettlerrelay.com
Telephone +44 (0) 1582 599 600 Fax +44 (0) 1582 599 700
AZ954
RELAY ORDERING DAT A
MEDIUM DUTY RELAYS
–
0.45 W COIL
COIL SPECIFICATIONS
Max. Continuous
VDC
4.0
6.7
8.0
12.0
16.0
32.0
Nominal Coil
VDC
Coil Resistance
±10%
20
56
80
180
320
1280
Must Operate
VDC
2.25
3.75
4.50
6.75
9.0
18.0
ORDER NUMBER*
3
5
6
9
AZ954X–1C–3D
AZ954X–1C–5D
AZ954X–1C–6D
AZ954X–1C–9D
AZ954X–1C–12D
AZ954X–1C–24D
AZ954Y–1C–3D
AZ954Y–1C–5D
AZ954Y–1C–6D
AZ954Y–1C–9D
AZ954Y–1C–12D
AZ954Y–1C–24D
12
24
MEDIUM DUTY RELAYS
–
0.36 W COIL
COIL SPECIFICATIONS
Max. Continuous
VDC
4.5
7.5
8.9
13.4
17.8
35.7
Nominal Coil
VDC
Coil Resistance
±10%
25
70
100
225
400
1600
Must Operate
VDC
2.25
3.75
4.50
6.75
9.0
18.0
ORDER NUMBER*
3
5
6
9
AZ954X–1C–3DM
AZ954X–1C–5DM
AZ954X–1C–6DM
AZ954X–1C–9DM
AZ954X–1C–12DM
AZ954X–1C–24DM
AZ954Y–1C–3DM
AZ954Y–1C–5DM
AZ954Y–1C–6DM
AZ954Y–1C–9DM
AZ954Y–1C–12DM
AZ954Y–1C–24DM
12
24
MECHANICAL DAT A
Dimensions in inches with metric equivalents in parentheses. Tolerance: ±0.010"
[1.52]
.060
[1.0]
5x .039±.005
AZ954X PC BOARD LAYOUT
[1.56]
[7.62]
.300
[11.81]
.465
[3.18]
.125
[15.75]
.620
.062
[10.16]
.400
[2.54]
.100
VIEWED TOWARD TERMINALS
AZ954X WIRING DIAGRAM
VIEWED TOWARD TERMINALS
AZ954Y WIRING DIAGRAM
VIEWED TOWARD TERMINALS
7
1
2
11
12
[2.54]
VIEWED TOWARD TERMINALS
2
11
6
7
[1.52]
.060
[1.0]
6x .039±.005
[7.62]
.300
[1.56]
AZ954Y PC BOARD LAYOUT
1
12
[2.54]
.100
.060
[1.52]
[7.62]
[10.75]
.300
.423
.062
[10.16]
.400
.100
LIGHT DUTY RELAYS
–
0.2 W COIL
COIL SPECIFICATIONS
Max. Continuous
VDC
6.0
9.8
12.0
17.8
23.6
47.3
Nominal Coil
VDC
Coil Resistance
±10%
45
120
180
400
700
2800
Must Operate
VDC
2.25
3.75
4.50
6.75
9.0
18.0
ORDER NUMBER*
3
5
6
9
AZ954X–1C–3DS
AZ954X–1C–5DS
AZ954X–1C–6DS
AZ954X–1C–9DS
AZ954X–1C–12DS
AZ954X–1C–24DS
AZ954Y–1C–3DS
AZ954Y–1C–5DS
AZ954Y–1C–6DS
AZ954Y–1C–9DS
AZ954Y–1C–12DS
AZ954Y–1C–24DS
12
24
*Add suffix “E” for epoxy sealed version. Add suffix “B” for Class B or “F” for Class F insulation system.