AQW61
H
EH
131
1
2
3
4
8
N.C.
N.O.
7
6
5
PhotoMOS
RELAYS
GU (General Use)-E Type
2-Channel (Form A Form B)
Type
3.2
.126
6.4
.252
9.86
.388
2.9
.114
6.4
.252
9.86
.388
FEATURES
1. Reinforced insulation 5,000 V type
More than 0.4 mm internal insulation dis-
tance between inputs and outputs. Con-
forms to EN41003, EN60950 (reinforced
insulation).
2. Compact 8-pin DIP size
The device comes in a compact (W)
6.4
×
(L)9.86
×
(H)3.2 mm
(W).252
×
(L).388
×
(H).126 inch
, 8-pin DIP
size (through hole terminal type).
3. Applicable for 1 Form A 1 Form B
use as well as two independent 1 Form
A and 1 Form B use
4. Controls low-level analog signals
PhotoMOS relays feature extremely low
closed-circuit offset voltage to enable
control of low-level analog signals without
distortion.
5. High sensitivity, high speed re-
sponse.
Can control a maximum 0.14 A load cur-
rent with a 5 mA input current. Fast oper-
ation speed of 0.5ms (typ.)
[N.O.].(AQW610EH)
6. Low-level off state leakage current
TYPICAL APPLICATIONS
Modem
Telephone equipment
Security equipment
Sensors
TYPES
*Indicate the peak AC and DC values.
Note:
For space reasons, the SMD terminal shape indicator "A" and the package type indicator "X" and "Z" are omitted from the seal.
Type
I/O isolation
voltage
Output rating*
Part No.
Packing quantity
Through hole
terminal
Surface-mount terminal
Load
voltage
Load
current
Tube packing style
Tape and reel packing style
Picked from the
1/2/3/4-pin side
Tube
Tape and
reel
Picked from the
5/6/7/8-pin side
AC/DC
type
Reinforced
5,000 V
350 V
120 mA
AQW610EH
AQW610EHA
AQW610EHAX
AQW610EHAZ
1 tube contains
40 pcs.
1 batch contains
400 pcs.
1,000 pcs.
400 V
100 mA
AQW614EH
AQW614EHA
AQW614EHAX
AQW614EHAZ
RATING
1. Absolute maximum ratings (Ambient temperature: 25
Item
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (peak AC)
°
C
77
°
F
)
Symbol
I
F
V
I
FP
P
V
AQW610EH (A)
AQW614EH (A)
Remarks
Input
50 mA
3 V
1 A
75 mW
R
f = 100 Hz, Duty factor = 0.1%
in
Output
L
350 V
400 V
Continuous load current
I
L
0.12 A (0.13 A)
0.1 A (0.13 A)
Peak AC, DC
( ): in case of using only 1a or 1b,
1 channel
100 ms (1 shot), V
Peak load current
Power dissipation
I
P
P
V
T
T
peak
0.36 A
0.3 A
L
= DC
out
800 mW
850 mW
5,000 V AC
°
C
–40
°
C
–40
Total power dissipation
I/O isolation voltage
T
iso
Temperature
limits
Operating
Storage
opr
–40
–40
°
C to +100
C to +85
°
F to +185
°
F to +212
°
F
°
Non-condensing at low temperatures
stg
°
F
mm
inch
TESTING