18
Am29F040B
21445E5
November 1, 2006
D A T A  S H E E T
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +125°C
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55°C to +125°C
Voltage with Respect to Ground 
V
CC
 (Note 
1)
 . . . . . . . . . . . . . . . . .–2.0 V to 7.0 V
A9, OE# (Note 
2)
. . . . . . . . . . . . .–2.0 V to 12.5 V
All other pins (Note 
1)
 . . . . . . . . . .–2.0 V to 7.0 V
Output Short Circuit Current (Note 
3)
 . . . . . . 200 mA
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V. During 
voltage transitions, inputs may undershoot V
SS
 to –2.0 V 
for periods of up to 20 ns. See Figure
 5
. Maximum DC 
voltage on input and I/O pins is V
CC
 + 0.5 V. During 
voltage transitions, input and I/O pins may overshoot to 
V
CC
 + 2.0 V for periods up to 20  ns. See Figure
 6
.
2. Minimum DC input voltage on A9 pin is –0.5 V. During 
voltage transitions, A9 and OE# may undershoot V
SS
 to 
–2.0 V for periods of up to 20 ns. See Figure
 5
. Maximum 
DC input voltage on A9 and OE# is 12.5 V which may 
overshoot to 13.5 V for periods up to 20 ns.
3. No more than one output shorted to ground at a time. 
Duration of the short circuit should not be greater than 
one second.
Stresses above those listed under “Absolute Maximum 
Ratings” may cause permanent damage to the device. This is 
a stress rating only; functional operation of the device at 
these or any other conditions above those indicated in the op-
erational sections of this specification is not implied. Expo-
sure of the device to absolute maximum rating conditions for 
extended periods may affect device reliability.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
) . . . . . . . . . . . 0°C to +70°C
Industrial (I) Devices
Ambient Temperature (T
A
) . . . . . . . . . –40°C to +85°C
Extended (E) Devices
Ambient Temperature (T
A
) . . . . . . . . –55°C to +125°C
V
CC 
Supply Voltages
V
CC
 for ± 5% devices. . . . . . . . . . .+4.75 V to +5.25 V
V
CC
 for ± 10% devices . . . . . . . . . . . +4.5 V to +5.5 V
Operating ranges define those limits between which the 
functionality of the device is guaranteed.
20 ns
20 ns
+0.8 V
–0.5 V
20 ns
–2.0 V
 Figure 5. Maximum Negative 
Overshoot Waveform
20 ns
20 ns
V
CC 
+2.0 V
V
CC 
+0.5 V
20 ns
2.0 V
 Figure 6. Maximum Positive 
Overshoot Waveform