Am27C128
7
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
OTP Products. . . . . . . . . . . . . . . . . .
–65
°
C to +125
°
C
All Other Products . . . . . . . . . . . . . . –65
°
C to +150
°
C
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55
°
C to +125
°
C
Voltage with Respect to V
SS
All pins except A9, V
PP
, V
CC
. . –0.6 V to V
CC
+ 0.6 V
A9 and V
PP
(Note 2) . . . . . . . . . . . . .–0.6 V to 13.5 V
V
CC
(Note 1). . . . . . . . . . . . . . . . . . . . .–0.6 V to 7.0 V
Notes:
1.
Minimum DC voltage on input or I/O pins –0.5 V During
voltage transitions, the input may overshoot V
SS
to –2.0 V
for periods of up to 20 ns. Maximum DC voltage on input
and I/O pins is V
CC
+ 5 V During voltage transitions, input
and I/O pins may overshoot to V
CC
+ 2.0 V for periods up
to 20 ns.
2. Minimum DC input voltage on A9 is –0.5 V During voltage
transitions, A9 and V
PP
may overshoot V
SS
to –2.0 V for
periods of up to 20 ns. A9 and V
PP
must not exceed +13.5
V at any time.
Stresses above those listed under “Absolute Maximum Rat-
ings” may cause permanent damage to the device. This is a
stress rating only; functional operation of the device at these
or any other conditions above those indicated in the opera-
tional sections of this specification is not implied. Exposure of
the device to absolute maximum ratings for extended periods
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
) . . . . . . . . . . .0
°
C to +70
°
C
Industrial (I) Devices
Ambient Temperature (T
A
) . . . . . . . . .
–40
°
C to +85
°
C
Extended (E) Devices
Ambient Temperature (T
A
) . . . . . . . .–55
°
C to +125
°
C
Supply Read Voltages
V
CC
for ± 5% devices . . . . . . . . . . +4.75 V to +5.25 V
V
CC
for ± 10% devices . . . . . . . . . +4.50 V to +5.50 V
Operating ranges define those limits between which the func-
tionality of the device is guaranteed.