ASAHI KASEI 
[AK4702] 
MS0187-E-00 
2002/11 
- 20 - 
n
 System Reset and Power-down control 
The AK4702 should be reset once by bringing PDN = “L” upon power-up. The AK4702 has several power-down modes. 
The PDN pin, MUTE bit and STBY bit control them as shown in Table 9 and Table 10. 
 PDN pin: Power down pin.  
“H”:  Normal operation 
“L”:  Device power down. 
 MUTE bit: Analog Mute bit. 
“1”:  Mute all analog outputs 
“0”: Normal operation 
STBY bit : Standby bit. 
“1”:  Standby mode, DAC is powered down, volume is fixed to 0dB, the analog audio/video paths are 
 fixed to TV-VCR loop-through. 
“0”: Normal operation. 
After when the PDN pin is set to “H”, the AK4702 is in standby mode and muted. To exit the mute and enter standby mode, 
set the MUTE bit to “0” and the STBY bit to “1”. To use the DAC or change analog switches, set the STBY bit to “0”. The 
DAC will power up and the internal timing starts clocking LRCK “
↑
” after exiting reset and power down states by MCLK. 
The AK4702 is in power-down mode until MCLK and LRCK are input. 
Mode 
PDN pin 
MUTE 
bit 
STBY 
bit 
MCLK, 
BICK, 
LRCK 
DAC 
Analog 
outputs 
Register 
control 
0 
Device power-down 
“L” 
* 
* 
Not Needed 
Powered 
Down 
Powered 
Down 
GND 
Not Available 
1 
Standby and mute 
(default) 
“H” 
1 
1 
Not Needed 
GND 
Available 
2 
Standby 
“H” 
0 
1 
Not Needed 
Powered 
Down 
fixed to 
TV-VCR 
loop-through 
GND 
Active 
Available 
3 
4 
Mute 
“H” 
“H” 
1 
0 
0 
0 
Needed 
Needed 
Active 
Active 
Available 
Available 
Normal operation 
Table 9. Power-down modes (audio) 
Mode 
PDN pin 
STBY bit 
Video outputs 
TVFB, 
TVSB 
VCRSB 
0 
Power-down 
“L” 
* 
Hi-z 
Hi-z 
Internally pulled down by 
120kohm(typ) resister 
1 
Standby 
“H” 
1 
Active 
(Path is fixed) 
Active 
Active 
Active 
2 
Normal operation 
“H” 
0 
Active 
Active 
Table 10. Power-down modes (video)