BUSY and DOUT goes to “L” from Hi-Z state at the falling edge of CSN.  The AK4180 latches the 8bit control word serially via 
DIN at the rising edge of DCLK.  As the AK4180 starts the command decoding at the first “H” bit after CSN=”
↓
”, MSB of the 
command must be “H”.  
Tracking time is the period from the falling edge of 5
th
 DCLK to the falling edge of 8
th
 DCLK.  If SER/ DFR  =”1”, PD0=”0”, and 
if analog input is X-axis or Y-axis (the measurement is the pen position or pen pressure), the touch screen driver switches are 
turned ON for this 3DCLK period.  If SER/ DFR  =”0”, the switches are turned ON for the period from 5DCLK
↓
 to 20 DCLK
↓
.  
BUSY is “H” for one DCLK period, which is from 8DCLK
↓
 to 9DCLK
↓
.  BUSY is “L” for other period.  
The AK4180 outputs A/D data with MSB first via DOUT from the falling edge of 9
th
 DCLK. 
The AK4180 can output one A/D data per 16 DCLK clock cycles for the fastest way as shown in the dotted line of the above figure.   
 Pen Interrupt
The AK4180 has pen interrupt function to detect the pen touch. Pen interrupt function is enabled at power-down state.  YN pin is 
connected to GND at the PEN interrupt enabled state.  And XP pin is pulled up via an internal resistor (Ri), typically 20k ohm.  
PENIRQN pulled up via an external resistor, 100k ohm, is also connected to XP pin.  If the two plates are touched, the current 
flows via <VCC> – <Ri> – <XP> –<the plates> - <YN>.  The resistance of the plate is generally 1k ohm or less, PENIRQN is 
forced to “L” level.  If the pen is released, PENIRQN returns “H” level because two plates are disconnected, and the current 
doesn’t flow via two plates.   
If the plate is touched with pen or finger, PENIRQN goes to “L” at CSN=”H” unless both PD1 and PD0 is “1”.  PENIRQN is 
disabled and keeps “H” level regardless of the touched/non-touched state if CSN=”H”.   
The operation of PENIRQN is related to PD0 bit.  PD0 bit is updated at the rising edge of 8
th
 DCLK ( please see  “
 Power-down 
Control “ for the detail).  Therefore,  the last PD0 bit is valid until this timing.  (The internal voltage reference is controlled by only 
PD1 bit regardless of PD0 bit and CSN state.)  
i) The period from the 5
th
 DCLK 
↓
to the 20
th
 DCLK
↓
The behavior of PENIRQN is related to the selected analog input.  If the X-axis or Y-axis is selected as analog input, 
PENIRQN is forced to “L” regardless of the touched/non-touched state.  If the temperature, VBAT, or auxiliary inputs is 
selected, PENIRQN is forced to “H” regardless of the touched/non-touched state.  
ii) The period from CSN
↓
 to the 5
th
 DCLK.  
The behavior of PENIRQN is related to the combination of the last selected analog input channel, and the last PD0 bit.  If the 
last PD0 bit was set to “0”, PENIRQN is “H” while the plate is not pressed, and “L” while the plate is pressed regardless of the 
last analog input.  If the last PD0 bit was set to “1”, the last analog input decides the level of PENIRQN.   If the last analog 
input channel is ether X-axis or Y-axis, PENIRQN is  “L” for all the time in this period regardless of the touched/non-touched 
state.  On the other hand, if the last analog input is temperature, VBAT, or auxiliary inputs, PENIRQN is  “H” for all the time 
in this period regardless of the touched/non-touched state.  
iii) The period from the 20
th
 DCLK
↓
 to CSN
↑
The behavior of PENIRQN is related to the combination of the current selected analog input channel, and the current PD0 bit.  
If the current PD0 bit is set to “0”, PENIRQN is “H” while the plate is not pressed, and “L” while the plate is pressed 
regardless of the current selected analog input.  If the current PD0 bit is set to “1”, the current analog input decides the 
operation of PENIRQN.   If the current analog input channel is ether X-axis or Y-axis, PENIRQN is  “L” for all the time in this 
period regardless of the touched/non-touched state.  On the other hand, if the current analog input is temperature, VBAT, or 
auxiliary inputs, PENIRQN is  “H” for all the time in this period regardless of the touched/non-touched state..   
It is recommended that microcontroller mask the pseudo-interrupts while the control command is issued or A/D data is output.