AVX has developed the Active Filter Series to address the emissions and
susceptibility problems typical of today’s high speed digital circuits. The
Active Filter Series is the equivalent of back-to-back Zener diodes and an
EMC capacitor integrated into a single 0603 SMT case size. In its off
state the Active Filter Series can be used to attenuate EMI/RFI. Typical
values of attenuation at 3dB are 450MHz - 5000MHz, and typical values
of attenuation at 10dB are 950MHz - 2600MHz. A more definitive
representation of the filter effect is shown in the S
21
curve.
One of the specific advantages of the Active Filter Series is a consistent
EMI attenuation across a large bandwidth (without multiple frequency
poles occurring). This makes compliance to Electromagnetic
Susceptibility and Emission Specifications such as FCC Part 68, SAE
J1113 and IEC 61000-4-2 a much easier task for the designer.
0603 Active Filter Series
HOW TO ORDER
AFS
Style
Active
Filter
Series
0001
Case Size
0001 = 0603 Discrete
P
Termination
P = Plated (Ni/Sn Alloy)
D
Packaging Code
(Reel Size)
D = 7" Reel (1,000 pcs.)
R = 7" Reel (4,000 pcs.)
T = 13" Reel (10,000 pcs.)
GENERAL DESCRIPTION
PERFORMANCE CHARACTERISTICS
TEST
CONDITION
Peak Pulse
1ms, Ta
≤
25°C
Power Dissipation
Ta
≤
25°C, FR-4
Power Dissipation
Ta
≤
25°C, Alumina
Zener Voltage
1mA
Device Capacitance
1 MHz
Peak Current
Reverse Recovery
Time
Turn On Time
Operating Temperature
Storage Temperature
PARAMETER
LIMIT
7.5 W
225 mW
300 mW
80 V
27 pF (max)
2.5 A
≤
600 pS
≤
600 pS
-65 to +150°C
-65 to +150°C
MECHANICAL SPECIFICATIONS
CTE (PPM / °C)
6.1 ppm/°C
Thermal Conductivity
0.5 (W/cm)/°C
0
-5
-10
-15
-2010
100
Frequency (MHz)
1000
S
10000
S
21
Curve
10000
P
1000
100
10
10
100
Pulse Duration (
μ
S)
1000
10000
Typical Pulse Rating Curve
A KYOCERA GROUP COMPANY