ADXL50
REV. B
–3–
ABSOLUT E MAX IMUM RAT INGS*
Acceleration (Any Axis, Unpowered for 0.5 ms) . . . . . . 2000 g
Acceleration (Any Axis, Powered for 0.5 ms) . . . . . . . . . . 500 g
+V
S
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7.0 V
Output Short Circuit Duration
(V
PR
, V
OUT
, V
REF
T erminals to Common) . . . . . . . Indefinite
Operating T emperature . . . . . . . . . . . . . . . . .–55
°
C to +125
°
C
Storage T emperature . . . . . . . . . . . . . . . . . . . –65
°
C to +150
°
C
*
Stresses above those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. T his is a stress rating only; the functional
operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Package Characteristics
Package
u
JA
u
JC
Device Weight
10-Pin T O-100
130
°
C/W
30
°
C/W
5 Grams
ORDE RING GUIDE
T emperature
Range
Model
ADX L50JH
ADX L50AH
0
°
C to +70
°
C
–40
°
C to +85
°
C
PIN DE SCRIPT ION
+5 V
C2
T he power supply input pin.
Connection for an external bypass capacitor (nominally
0.022
μ
F) used to prevent oscillator switching noise
from interfering with other ADX L50 circuitry. Please
see the section on component selection.
Connections for the demodulator capacitor, nominally
0.022
μ
F. See the section on component selection for
application information.
COM T he power supply common (or “ground”) connection.
V
REF
Output of the internal 3.4 V voltage reference.
ST
T he digital self-test input. It is both CMOS and T T L
compatible.
V
PR
T he ADX L50 preamplifier output providing an output
voltage of 19 mV per g of acceleration.
V
OUT
Output of the uncommitted buffer amplifier.
V
IN–
T he inverting input of the uncommitted buffer amplifier.
C1
CONNE CT ION DIAGRAM
10-Header (T O-100)
WARNING!
ESD SENSITIVE DEVICE
C AUT ION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADX L 50 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. T herefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
5
6
6
7
8
8
9
10
1
1
2
3
3
4
4
A
S
V
IN–
V
OUT
V
PR
ST
V
REF
COM
C2
C1
C1
+5V
TOP VIEW
AXIS OF SENSITIVITY IS ALONG
A LINE BETWEEN PIN 5 AND
THE TAB.
THE CASE OF THE METAL CAN
PACKAGE IS CONNECTED TO
PIN 5 (COMMON).
ARROW INDICATES DIRECTION
OF POSITIVE ACCELERATION
ALONG AXIS OF SENSITIVITY.