ADS1244
15
SBAS273
www.ti.com
WEIGH SCALE SYSTEM
Figure 19 shows an example of a weigh scale system. OPA1,
OPA2, RG, and RF form a differential gain stage to amplify the
load cell output. The gain is equal to (1 + 2 RF/RG). Depend-
ing on the load cell, the typical gain setting is from 100 to 250.
RI and CI form a single-pole low-pass filter to band-limit the
FIGURE 19. Weigh Scale System.
ADS1244
VREFP
AVDD
SCLK
DRDY/ DOUT
P1.2/TA1
P1.0/TA0
XIN
XOUT/TCLK
CLK
DVDD
VREFN
GND
AINP
AVCC
1.8V ~ 3.6V
DVCC
AVSS
MSP430Fx41x
P1.1/TA0/MCLK
AINN
EMI Filter
DVSS
EMI Filter
OPA1(1)
OPA2(1)
NOTE: (1) OPA2335 or OPA2277 recommended.
5V
R
F
R
F
R
G
C
I
R
I
R
VR2
R
VR1
0.1
F
1
F
0.1
F
1
F
0.1
F
32.768kHz
0.1
F
Load Cell
R
I
differential gain stage noise and reduce mechanical vibration
noise from the load cell. The cutoff frequency of the low-pass
filter should be as low as possible to minimize the overall
system noise. The reference voltage is typically generated by
dividing down the supply voltage (RVR1, RVR2). Use a bypass
capacitor located as close to VREFP as possible.