REV. 0
–2–
ADP3607–SPECIFICATIONS
1, 2, 3
Parameter
Symbol
Condition
Min
Typ
Max
Units
OPERATING SUPPLY RANGE
V
S
I
S
3.0
3.3
5
V
SUPPLY CURRENT
Shutdown Mode
OUTPUT VOLTAGE
4
–40
°
C < T
A
< +85
°
C
V
SD
= V
IN
, –40
°
C < T
A
< +85
°
C
3.5
150
6
200
mA
μ
A
V
O
V
O
I
O
= 25 mA
I
O
= 10 mA to 50 mA
–40
°
C
≤
T
A
≤
+85
°
C
3.0 V
≤
V
S
≤
3.6 V
I
O
= 10 mA–25 mA
I
O
= 10 mA–50 mA
4.85
4.75
5
5
5.15
5.25
V
V
LOAD REGULATION
V
O
/I
O
0.3
0.25
mV/mA
mV/mA
OUTPUT RESISTANCE (Open Loop)
R
O
V
RIPPLE
11
OUTPUT RIPPLE VOLTAGE
C
IN
= C
O
= 4.7
μ
F
I
LOAD
= 25 mA
I
LOAD
= 50 mA
V
IN
= 3.3 V
–40
°
C < T
A
< +85
°
C
16
31
mV
mV
SWITCHING FREQUENCY
f
S
212
250
288
kHz
SHUTDOWN
Logic Input High
Input Current
Logic Input Low
Input Current
V
IH
I
IH
V
IL
I
IL
2.4
V
μ
A
V
μ
A
1
0.4
1
NOTES
1
Capacitors C
, C
and C
P
in the test circuit are 4.7
μ
F with 0.1
ESR. Capacitors with higher ESR may reduce output voltage and efficiency.
2
See Figure 1 conditions.
3
All limits at temperature extremes are guaranteed via correlation using standard Statistical Quality Control (SQC) methods.
4
For the adjustable version, a 1% resistor should be used to maintain output voltage tolerance. For both device types, tolerances can be improved by >1% using larger
value and lower ESR capacitors for C
O
and C
P
.
Specifications subject to change without notice.
(V
IN
= 3.3 V @ T
A
= +25
8
C, C
P
= C
O
= 4.7
m
F unless otherwise noted.)
ABSOLUTE MAXIMUM RATINGS
1
(T
A
= +25
°
C unless otherwise noted)
Input Voltage (V
IN
to GND) . . . . . . . . . . . . . . . . . . . . +7.5 V
Output Voltage (V
OUT
to GND) . . . . . . . . . . . . . . . . . . +12 V
Output Short Circuit Protection . . . . . . . . . . . . . . . . . . . 1 sec
θ
JA
,
SO-8 Package
2
. . . . . . . . . . . . . . . . . . . . . . . . . 150
°
C/W
θ
JA
,
TSSOP-8 Package
2
. . . . . . . . . . . . . . . . . . . . . . 208
°
C/W
Operating Temperature Range . . . . . . . . . . . –40
°
C to +85
°
C
Storage Temperature Range . . . . . . . . . . . . –65
°
C to +150
°
C
Lead Temperature Range (Soldering 10 sec) . . . . . . . .+300
°
C
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . .+215
°
C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . .+220
°
C
NOTES
1
This is a stress rating only, operation beyond these limits can cause the device to be
permanently damaged.
2
θ
JA
is specified for worst case conditions with device soldered on a circuit board.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADP3607 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
ORDERING GUIDE
Model
Output Voltage
Package Option*
ADP3607AR-5
ADP3607AR
ADP3607ARU-5
ADP3607ARU
5 V, 50 mA
Adjustable, 50 mA
5 V, 50 mA
Adjustable, 50 mA
SO-8
SO-8
RU-8
RU-8
*SO = Small Outline Package; RU = Thin Small Outline Package.