![](http://datasheet.mmic.net.cn/310000/ADM1232_datasheet_16241440/ADM1232_3.png)
ADM1232
–3–
REV. B
ORDE RING GUIDE
T emperature
Range
–40
°
C to +85
°
C
–40
°
C to +85
°
C
–40
°
C to +85
°
C
–40
°
C to +85
°
C
Package
Options*
Model
ADM1232ARM
ADM1232AN
ADM1232ARW
ADM1232ARN
RM-8
N-8
R-16
R-8
*N= Plastic DIP; R = Small Outline; RM = microSOIC.
ABSOLUT E MAX IMUM RAT INGS*
(T
A
= +25
°
C unless otherwise noted)
V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5.5 V
Logic Inputs . . . . . . . . . . . . . . . . . . . . . –0.3 V to V
CC
+ 0.3 V
Storage T emperature Range . . . . . . . . . . . . –65
°
C to +150
°
C
Lead T emperature (Soldering, 10 sec) . . . . . . . . . . . . +300
°
C
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . +215
°
C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . +220
°
C
N-8
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 mW
Derate by 13.5 mW/
°
C above 25
°
C
θ
JA
T hermal Impedance . . . . . . . . . . . . . . . . . . . . . 100
°
C/W
R-16
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 mW
Derate by 12 mW/
°
C above 25
°
C
θ
JA
T hermal Impedance (Still Air) . . . . . . . . . . . . . . 73
°
C/W
RM-8
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 mW
Derate by 12 mW/
°
C above 25
°
C
θ
JA
T hermal Impedance (Still Air) . . . . . . . . . . . . . 206
°
C/W
R-8
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900
μ
W
Derate by 12 mW/
°
C above 25
°
C
θ
JA
T hermal Impedance (Still Air) . . . . . . . . . . . . . 153
°
C/W
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. T his is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum ratings
for extended periods of time may affect device reliability.
C AUT ION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADM1232 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. T herefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
ESD SENSITIVE DEVICE