ADG661/ADG662/ADG663
–4–
REV. 0
C AUT ION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADG661/ADG662/ADG663 features proprietary ESD protection circuitry, per-
manent damage may occur on devices subjected to high energy electrostatic discharges. T here-
fore, proper ESD precautions are recommended to avoid performance degradation or loss of
functionality.
WARNNG
ESD SENSITIVE DEVICE
ORDE RING GUIDE
T emperature
Range
–40
°
C to +85
°
C
–40
°
C to +85
°
C
–40
°
C to +85
°
C
Package
Description
Package
Option
Model
ADG661BRU
ADG662BRU
ADG663BRU
16-Lead T SSOP
16-Lead T SSOP
16-Lead T SSOP
RU-16
RU-16
RU-16
ABSOLUT E MAX IMUM RAT INGS
1
(T
A
= +25
°
C unless otherwise noted)
V
DD
to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+44 V
V
DD
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +25 V
V
SS
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –25 V
Analog, Digital Inputs
2
. . . . . . . . . . . V
SS
–2 V to V
DD
+2 V or
30 mA, Whichever Occurs First
Continuous Current, S or D . . . . . . . . . . . . . . . . . . . . . 30 mA
Peak Current, S or D . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA
(Pulsed at 1 ms, 10% Duty Cycle max)
Operating T emperature Range
Industrial (B Version) . . . . . . . . . . . . . . . . . –40
°
C to +85
°
C
Storage T emperature Range . . . . . . . . . . . . . –65
°
C to +150
°
C
Junction T emperature . . . . . . . . . . . . . . . . . . . . . . . . . +150
°
C
T SSOP Package, Power Dissipation . . . . . . . . . . . . . . 450 mW
θ
JA
T hermal Impedance . . . . . . . . . . . . . . . . . . . . . . . 115
°
C/W
θ
JC
T hermal Impedance . . . . . . . . . . . . . . . . . . . . . . . . 35
°
C/W
Lead T emperature, Soldering
Vapor Phase (60 secs) . . . . . . . . . . . . . . . . . . . . . . . +215
°
C
Infrared (15 secs) . . . . . . . . . . . . . . . . . . . . . . . . . . . +220
°
C
NOT ES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. T his is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability. Only one absolute
maximum rating may be applied at any one time.
2
Overvoltages at IN, S or D will be clamped by internal diodes. Current should be
limited to the maximum ratings given.