Table 5. F
1–4
Frequency Selection
S1
S0
OSC Relation
1
0
0
OSC/2
19
0
1
OSC/2
18
1
0
OSC/2
17
1
1
OSC/2
16
Rev. A | Page 15 of 20
F
1–4
at Nominal OSC (Hz)
2
0.86
1.72
3.43
6.86
1
F
1–4
is a binary fraction of the internal oscillator frequency.
2
Values are generated using the nominal frequency of 450 kHz.
Example
In this example, with ac voltages of ±30 mV peak applied to
V1 and ±165 mV peak applied to V2, the expected output
frequency is calculated as
F
1–4
= OSC/2
19
Hz, S0 = S1 = 0
V1
rms
= 0.03/√2 V
V2
rms
= 0.165/√2 V
V
REF
= 2.45 V (nominal reference value)
If the on-chip reference is used, actual output frequencies
may vary from device to device due to the reference tolerance
of ±200 mV.
×
×
×
=
Freq
175
.
204
.
45
.
2
2
165
.
03
.
×
75
.
494
2
=
×
=
×
1
1
F
F
(11)
Table 6. Maximum Output Frequency on F1 and F2
S1 S0 OSC Relation
0
0
0.204 × F
1
0
1
0.204 × F
2
1
0
0.204 × F
3
1
1
0.204 × F
4
Max Frequency
1
or AC Inputs (Hz)
0.175
0.35
0.70
1.40
1
Values are generated using the nominal frequency of 450 kHz.
Frequency Output CF
The pulse output CF (calibration frequency) is intended for
calibration purposes. The output pulse rate on CF can be up to
2048 times the pulse rate on F1 and F2. The lower the F
1–4
frequency selected, the higher the CF scaling (except for the
high frequency mode SCF = 0, S1 = S0 = 1). Table 7 shows how
the two frequencies are related, depending on the states of the
logic inputs S0, S1, and SCF. Due to its relatively high pulse
rate, the frequency at the CF logic output is proportional to the
instantaneous real power. As with F1 and F2, CF is derived
from the output of the low-pass filter after multiplication.
However, because the output frequency is high, this real
power information is accumulated over a much shorter time.
Therefore, less averaging is carried out in the digital-to-
frequency conversion. With much less averaging of the real
power signal, the CF output is much more responsive to power
fluctuations (see the signal processing block diagram shown in
Figure 15).
Table 7. Maximum Output Frequency on CF
SCF
S1
S0
1
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
CF Max for AC Signals (Hz)
1
128 × F1, F2 = 22.4
64 × F1, F2 = 11.2
64 × F1, F2 = 22.4
32 × F1, F2 = 11.2
32 × F1, F2 = 22.4
16 × F1, F2 = 11.2
16 × F1, F2 = 22.4
2048 × F1, F2 = 2.867 kHz
1
Values are generated using the nominal frequency of 450 kHz.
SELECTING A FREQUENCY FOR AN ENERGY
METER APPLICATION
As shown in Table 5, the user can select one of four frequencies.
This frequency selection determines the maximum frequency
on F1 and F2. These outputs are intended for driving an energy
register (electromechanical or other). Because only four
different output frequencies can be selected, the available
frequency selection has been optimized for a meter constant
of 100 imp/kWh with a maximum current of between 10 A
and 120 A. Table 8 shows the output frequency for several
maximum currents (I
MAX
) with a line voltage of 220 V. In all
cases, the meter constant is 100 imp/kWh.
Table 8. F1 and F2 Frequency at 100 imp/kWh
I
MAX
(A)
F1 and F2 (Hz)
12.5
0.076
25.0
0.153
40.0
0.244
60.0
0.367
80.0
0.489
120.0
0.733
The F
1–4
frequencies allow complete coverage of this range of
output frequencies (F1, F2). When designing an energy meter,
the nominal design voltage on Channel V2 (voltage) should be
set to half-scale to allow for calibration of the meter constant.
The current channel should also be no more than half scale
when the meter sees maximum load. This allows overcurrent
signals and signals with high crest factors to be accommodated.
Table 9 shows the output frequency on F1 and F2 when both
analog inputs are half scale. The frequencies in Table 9 align
very well with those in Table 8 for maximum load.
Table 9. F1 and F2 Frequency with Half-Scale AC Inputs
Frequency on F1 and F2—
CH1 and CH2 Half-Scale AC Input
1
0
0
0.86
0.051 × F
1
0
1
1.72
0.051 × F
2
1
0
3.43
0.051 × F
3
1
1
6.86
0.051 × F
4
S1
S0
F
1–4
(Hz)
0.044 Hz
0.088 Hz
0.176 Hz
0.352 Hz
1
Values are generated using the nominal frequency of 450 kHz.
相關(guān)PDF資料
PDF描述
ADE7769AR-REF Energy Metering IC with Integrated Oscillator and No-Load Indication
ADE7769AR-RL Energy Metering IC with Integrated Oscillator and No-Load Indication
ADE7769ARZ Energy Metering IC with Integrated Oscillator and No-Load Indication
ADE7769ARZ-RL Energy Metering IC with Integrated Oscillator and No-Load Indication
ADEL2020 Improved Second Source to the EL2020(EL2020的改進(jìn)型第二級放大器)
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADE7769AR-REF 制造商:AD 制造商全稱:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and No-Load Indication
ADE7769AR-RL 制造商:Analog Devices 功能描述:Energy Measurement 16-Pin SOIC N T/R 制造商:Analog Devices 功能描述:ENERGY MEASUREMENT 16SOIC - Tape and Reel
ADE7769ARZ 功能描述:IC ENERGY METERING 1PHASE 16SOIC RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:2,500 系列:*
ADE7769ARZ-RL 功能描述:IC ENERGY METERING 1PHASE 16SOIC RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:2,500 系列:*
ADE7816 制造商:AD 制造商全稱:Analog Devices 功能描述:Six Current Channels, One Voltage Channel