參數(shù)資料
型號(hào): AD7151BRMZ-REEL
廠商: Analog Devices Inc
文件頁數(shù): 9/28頁
文件大?。?/td> 0K
描述: IC CAP CONV 1CH ULT LP 10MSOP
標(biāo)準(zhǔn)包裝: 3,000
類型: 電容數(shù)字轉(zhuǎn)換器
輸入類型: 電壓
輸出類型: 數(shù)字
接口: 2 線串口
電流 - 電源: 120µA
安裝類型: 表面貼裝
封裝/外殼: 10-TFSOP,10-MSOP(0.118",3.00mm 寬)
供應(yīng)商設(shè)備封裝: 10-MSOP
包裝: 帶卷 (TR)
AD7151
Rev. 0 | Page 17 of 28
TIMEOUT REGISTER
When either the approaching or receding timeout elapses (that
is, after the defined number of CDC conversions is counted),
the data average (and thus the thresholds) is forced to follow the
new CDC data value immediately.
Address Pointer 0x0A
8 Bits, Read/Write, Factory Preset 0x86
Table 9. Timeout Register Bit Map
Bit
Bits [7:4]
When the timeout register equals 0, timeouts are disabled.
Bits [3:0]
Mnemonic
TimeOutApr
TimeOutRec
Default
0x08
0x06
DATA AVERAGE
+ SENSITIVITY
LARGE CHANGE IN DATA
TOWARDS THRESHOLD
DATA AVERAGE
THRESHOLD
TIME
TIMEOUT APPROACHING
07
08
6-
0
2
6
The register sets timeouts for the adaptive threshold mode.
The approaching timeout starts when the CDC data crosses the
data average ± sensitivity band toward the threshold, according
to the selected positive, negative, or window threshold mode. The
approaching timeout elapses after the number of conversion cycles
equals 2TimeOutApr, where TimeOutApr is the value of the four most
significant bits of the timeout register.
Figure 37. Threshold Timeout Approaching
After a Large Change in CDC Data Toward Threshold
The receding timeout starts when the CDC data crosses the
data average ± sensitivity band away from the threshold,
according to the selected positive or negative threshold mode.
The receding timeout is not used in the window threshold
mode. The receding timeout elapses after the number of
conversion cycles equals 2TimeOutRec, where TimeOutRec is the
value of the four least significant bits of the timeout register.
DATA AVERAGE
+ SENSITIVITY
LARGE CHANGE IN DATA
AWAY FROM THE THRESHOLD
DATA AVERAGE
THRESHOLD
TIME
TIMEOUT RECEDING
07
08
6-
0
27
Figure 38. Threshold Timeout Receding
After a Large Change in CDC Data Away from Threshold
相關(guān)PDF資料
PDF描述
AD7152BRMZ-REEL IC CDC 12BIT 2/4CH 10MSOP
AD7156BCPZ-REEL IC CDC 2CH 12BIT 1.8V 10-LFCSP
AD7224CQ IC DAC 8BIT W/AMP 18-CDIP
AD723ARUZ-REEL7 IC ENCODER RGB-NTSC/PAL 28-TSSOP
AD7247BQ IC DAC 12BIT W/AMP W/BUFF 24CDIP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AD7152 制造商:AD 制造商全稱:Analog Devices 功能描述:12-Bit Capacitance-to-Digital Converter
AD7152BRMZ 功能描述:IC CDC 12BIT 2/4CH 10MSOP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - ADCs/DAC - 專用型 系列:- 產(chǎn)品培訓(xùn)模塊:Data Converter Basics 標(biāo)準(zhǔn)包裝:1 系列:- 類型:電機(jī)控制 分辨率(位):12 b 采樣率(每秒):1M 數(shù)據(jù)接口:串行,并聯(lián) 電壓電源:單電源 電源電壓:2.7 V ~ 3.6 V,4.5 V ~ 5.5 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:100-TQFP 供應(yīng)商設(shè)備封裝:100-TQFP(14x14) 包裝:剪切帶 (CT) 其它名稱:296-18373-1
AD7152BRMZ-REEL 功能描述:IC CDC 12BIT 2/4CH 10MSOP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - ADCs/DAC - 專用型 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:50 系列:- 類型:數(shù)據(jù)采集系統(tǒng)(DAS) 分辨率(位):16 b 采樣率(每秒):21.94k 數(shù)據(jù)接口:MICROWIRE?,QSPI?,串行,SPI? 電壓電源:模擬和數(shù)字 電源電壓:1.8 V ~ 3.6 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:40-WFQFN 裸露焊盤 供應(yīng)商設(shè)備封裝:40-TQFN-EP(6x6) 包裝:托盤
AD7153 制造商:AD 制造商全稱:Analog Devices 功能描述:12-Bit Capacitance-to-Digital Converter
AD7153BRMZ 功能描述:IC CDC 12BIT 1/2CH 10MSOP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - ADCs/DAC - 專用型 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:50 系列:- 類型:數(shù)據(jù)采集系統(tǒng)(DAS) 分辨率(位):16 b 采樣率(每秒):21.94k 數(shù)據(jù)接口:MICROWIRE?,QSPI?,串行,SPI? 電壓電源:模擬和數(shù)字 電源電壓:1.8 V ~ 3.6 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:40-WFQFN 裸露焊盤 供應(yīng)商設(shè)備封裝:40-TQFN-EP(6x6) 包裝:托盤