CD54ACT02, CD74ACT02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SCHS309B
–
JANUARY 2001
–
REVISED MAY 2002
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
) (see Note 1)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
) (see Note 1)
Continuous output current, I
O
(V
O
= 0 to V
CC
)
Continuous current through V
CC
or GND
Package thermal impedance,
θ
JA
(see Note 2): E package
–
0.5 V to 6 V
±
20 mA
±
50 mA
±
50 mA
±
100 mA
80
°
C/W
86
°
C/W
–
65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
°
C
–
40
°
C TO
85
°
C
–
55
°
C TO
125
°
C
UNIT
MIN
MAX
MIN
MAX
MIN
MAX
VCC
VIH
VIL
VI
VO
IOH
IOL
t/
v
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs
, literature number SCBA004.
Supply voltage
4.5
5.5
4.5
5.5
4.5
5.5
V
High-level input voltage
2
2
2
V
Low-level input voltage
0.8
0.8
0.8
V
Input voltage
0
VCC
VCC
–
24
0
VCC
VCC
–
24
0
VCC
VCC
–
24
V
Output voltage
0
0
0
V
High-level output current
mA
Low-level output current
24
24
24
mA
Input transition rise or fall rate
10
10
10
ns/V
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25
°
C
–
40
°
C TO
85
°
C
–
55
°
C TO
125
°
C
UNIT
MIN
4.4
MAX
MIN
4.4
MAX
MIN
4.4
MAX
IOH =
–
50
μ
A
IOH =
–
24 mA
IOH =
–
50 mA
IOH =
–
75 mA
IOL = 50
μ
A
IOL = 24 mA
IOL = 50 mA
IOL = 75 mA
4.5 V
VOH
VI= VIHor VIL
VI = VIH or VIL
4.5 V
3.94
3.8
3.7
V
5.5 V
3.85
5.5 V
3.85
4.5 V
0.1
0.1
0.1
VOL
VI= VIHor VIL
VI = VIH or VIL
4.5 V
0.36
0.44
0.5
V
5.5 V
1.65
5.5 V
1.65
±
1
40
II
ICC
ICC
Ci
VI = VCC or GND
VI = VCC or GND,
VI = VCC
–
2.1 V
5.5 V
±
0.1
±
1
80
μ
A
μ
A
mA
IO = 0
5.5 V
4
4.5 V to 5.5 V
2.4
2.8
3
10
10
10
pF
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-
transmission-line drive capability at 85
°
C and 75-
transmission-line drive capability at 125
°
C.