Philips Semiconductors
Product specification
SA5775A
Differential air-core meter driver
2000 Aug 10
4
Table 2.
SA5775A Pin Descriptions for the D Package (Small Outline)
Pin #
Name
Function
1.
SIN–
Negative output connection to the SIN coil of the gauge.
2.
SIN+
Positive output connection to the SIN coil of the gauge.
3.
NC
No connect
4.
NC
No connect
5.
NC
No connect
6.
AGND
Ground for VIGN supply. Pins 6, 20 and 23 connected on the circuit board.
7.
VIGN
Analog supply. Nominally 14.0V.
8.
DATAOUT
Serial data output. Output of the internal shift register. When a new data word is shifted in, the old word is shifted out the
DATAOUT pin.
9.
DATAIN
Serial data input. A new data word is serially shifted into the part on the rising edge of SCLK. The data is shifted in MSB first.
10.
NC
No connect
11.
NC
No connect
12.
NC
No connect
13.
VCC
5 V logic supply. The internal latches and registers are set to zero on the rising edge of this signal.
14.
OE
Output drivers are turned off when this input is low. Current draw is minimized.
15.
SCLK
Serial clock input. Data is loaded into the part on the rising edge of SCLK.
16.
CS
Active high chip select input. When CS is high, the part is enabled to receive a new serial input word. The high-to-low
transition of CS loads the new 10-bit word into the DAC registers and updates the output.
17.
NC
No connect
18.
NC
No connect
19.
ST
Status output from this IC to indicate that the outputs have been disabled. The outputs may be disabled due to shorted out-
puts, over temperature conditions, power up reset, or output enable control pin. This output is an open drain output. Multiple
status outputs may be wire OR’ed together. This output is low when the outputs are disabled due to a fault condition.
20.
DGND
Ground for VCC supply. Connect to Pins 6 and 23.
21.
NC
No connect
22.
NC
No connect
23.
AGND
Ground for VBB supply. Connect to Pins 6 and 20.
24.
NC
No connect
25.
NC
No connect
26.
NC
No connect
27.
COS–
Negative output connection to the COS coil of the gauge.
28.
COS+
Positive output connection to the COS coil of the gauge.
ABSOLUTE MAXIMUM RATINGS
SYMBOL
PARAMETER
RATING
UNIT
VIGN
Analog supply
-1 to +23
V
VCC
Digital supply
-1 to +6
V
DGND to AGND
Ground difference
-0.3 to +0.3
V
VIN
Digital input voltage, Data In, OE, CS, SCLK
-1 to +7
V
PD
Power dissipation (TA = 25°C)1
D and N packages
1500
mW
TA
Ambient operating temperature
–40 to +85
°C
TJ
Junction temperature
150
°C
θJA
DIP and SO packages
90
°C/W
NOTE:
1. For power dissipation ratings in still air, derate above 25
°C at the following rates:
D and N packages at 12mW/
°C