Relay Socket with Small Switching Relay
1/2
Socket with relay (2 changeover contacts) and status indication
Data sh eet
WAGO Kontakttechnik GmbH & Co. KG
Postfach 2880 D-32385 Minden
Tel.:
05 71 / 8 87-0
E-Mail:
info@wago.com
Hansastr. 27 D-32423 Minden
Fax.:
05 71 / 8 87-169 Web:
http://www.wago.com
Subject to design changes
23.03.2010 / dj31200e
14
24
12
22
11
21
A1
+
A2
-
Similar photo
Description
Item-No.
Pack.-unit
pcs
Socket with relay, DC 24 V, 2 changeover contacts
788-312
1
Relay socket for DIN 35 carrier rails.
Status indication through pluggable LED module (red).
Insulated, pluggable jumper system suitable for both coil
and load side.
CAGE CLAMP S connection.
Solid wires, fine-stranded wires with crimped ferrules or
ultrasonically bonded wire ends can be inserted directly.
Quick exchange of the relay and the status indication
during maintenance, without having to detach the wiring.
Safe electrical isolation in accordance with DIN VDE 0140
Part 1.
DC-Load limiting value graph
300
200
100
50
40
30
20
10
0,1 0,2
0,5
1
2
5
10
20
2 contacts in series
2 poles resistive load
Current [A]
V
olt
age
[V]
1 contact
Note: Inductive loads have to be attenuated by
an appropriate protective circuit in order to
protect relay coils and contacts !
Technical Data
Contact material
AgNi 90/10
Input nominal voltage UN
DC 24 V
Input voltage range
UN ± 10 %
Current input at UN (20 °C)
19 mA
Max. switching voltage
AC 250 V
Max. making current (resistive)
at 10 % continuous duty
4 s (AC) 15 A
Max. continuous current
2 x 8 A (2 x 3 A at 70°C)
Max. switching power
(resistive)
2 x AC 2000 VA
(resistive)
DC see load limiting value graph
Max. number of switching
operations with/without load
6 min
-1 / 1200 min-1
Operating power
400 mWtyp.
Pull-in/dropout/bounce timetyp. 7 ms / 2 ms / 3 ms
Operation at normal rating
100 % continuous duty
Dielectric strength
contact/coil
5 kV
open contact
1 kV
Nominal voltage acc. to
VDE 0110 Part1 / 4.97
IEC 60664-1
250 V / 4 kV / 3
Mechanical life
30 x 10
6 switching operations
Degree of protection
IP 20
Relay type
RT 2
Ambient operating temperature -25 °C ... +50 °C (70°C see above)
Storage temperature
-40 °C ... +70 °C
Dimensions (WxHxD)
(15x53*x86) mm / (0.59x2.09x3.39) in
* from upper edge of DIN 35 rail